Spectrophotometer

Labzee Spectrophotometer are designed to measure intensity of light at specific wavelengths. They can store and analyze results for trend tracking and detailed reporting. Their multiple sample holding capability provides flexibility for different specimen types and sizes. They feature touchscreen display for easy operation and efficient data interpretation. Our Spectrophotometer range includes Atomic Absorption Spectrophotometer, Double Beam Spectrophotometer, Flame Photometer, ICP Spectrometer, Micro Spectrophotometer, NIR Spectrophotometer, UV/Vis Spectrophotometer, and X-Ray Fluorescence Spectrometer.

Atomic Absorption Spectrophotometer BZAAS-501

Wavelength Range: 190 to 900 nm

Spectral Bandwidth: 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic adjustable

Wavelength Accuracy: ≤ 0.15 nm

Wavelength Repeatability: ± 0.1 nm

$13,040.00

Atomic Absorption Spectrophotometer BZAAS-502

Wavelength Range : 190 to 900 nm

Spectral Bandwidth: 0.1, 0.2, 0.4, 1.0 and 2.0 nm

Wavelength Accuracy: ±0.15 nm

Wavelength Receptivity: ≤0.04 nm

Atomic Absorption Spectrophotometer BZAAS-503

Wavelength Range: 190 to 900 nm

Wavelength Accuracy: ±0.5 nm

Wavelength Repeatability: 0.3 nm (single direction)

Spectrum Bandwidth: 0.2 nm, 0.4 nm, 0.7nm, 1.4 nm, 2.4 nm, 5.0 nm

Double Beam Spectrophotometer BZSD-501

Wavelength Range: 190 to 1100 nm

Spectral Bandwidth: 0.5, 1.0, 2.0, 4.0 nm

Wavelength Accuracy: ±0.1 nm (D2 656.1 nm), ±0.3 nm full range

Stray Light: 0.03%T at 220 nm, 360 nm

$5,550.00

Flame Photometer BZFP-502

Range: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Li</strong></td><td>optional</td></tr></table>

Linearity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.195ppm(0.39 to 3.12)ppm</td></tr><tr><td><strong>Na</strong></td><td>0.69ppm(1.15 to 9.2)ppm</td></tr><tr><td><strong>Li</strong></td><td>optional</td></tr></table>

Repeatability: 1 % CV for 20 consecutive samples

Respond time : <8s

Flame Photometer BZFP-503

Sensitivity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Li</strong></td><td>0.1ppm</td></tr></table>

Range: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Li</strong></td><td>0 to 100 ppm</td></tr></table>

Linearity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.195ppm(0.39 to 3.12)ppm</td></tr><tr><td><strong>Na</strong></td><td>0.69ppm(1.15 to 9.2)ppm</td></tr><tr><td><strong>Li</strong></td><td>0.15ppm(0.25 to 5)ppm</td></tr></table>

Repeatability: 1 % CV for 20 consecutive samples

Flame Photometer BZFP-504

Sensitivity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.01ppm</td></tr><tr><td><strong>Na</strong></td><td>0.01ppm</td></tr><tr><td><strong>Ca</strong></td><td>2 ppm</td></tr></table>

Range: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0 to 100 ppm</td></tr><tr><td><strong>Na</strong></td><td>0 to 160 ppm</td></tr><tr><td><strong>Ca</strong></td><td>0 to 1000 ppm</td></tr></table>

Linearity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>00.195ppm(0.39 to 3.12)ppm</td></tr><tr><td><strong>Na</strong></td><td>0.69ppm(1.15 to 9.2)ppm</td></tr><tr><td><strong>Li</strong></td><td>0.15ppm(0.25 to 5)ppm</td></tr><tr><td><strong>Ca</strong></td><td>3ppm(5 to 100)ppm</td></tr></table>

Repeatability: 1 % CV for 20 consecutive samples

Flame Photometer BZFP-505

Sensitivity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Ba</strong></td><td>6 ppm</td></tr></table>

Range: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Ba</strong></td><td>0 to 3000 ppm</td></tr></table>

Linearity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Ca</strong></td><td>3ppm(5 to 100)ppm</td></tr><tr><td><strong>Ba</strong></td><td>9ppm</td></tr></table>

Repeatability: 1 % CV for 20 consecutive samples

Flame Photometer BZFP-506

Sensitivity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.01ppm</td></tr><tr><td><strong>Na</strong></td><td>0.01ppm</td></tr><tr><td><strong>Li</strong></td><td>0.1ppm</td></tr><tr><td><strong>Ca</strong></td><td>2ppm</td></tr></table>

Range: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0 to 100 ppm</td></tr><tr><td><strong>Na</strong></td><td>0 to 160 ppm</td></tr><tr><td><strong>Li</strong></td><td>0 to 100 ppm</td></tr><tr><td><strong>Ca</strong></td><td>0 to 1000 ppm</td></tr></table>

Linearity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.195ppm(0.39 to 3.12)ppm</td></tr><tr><td><strong>Na</strong></td><td>0.69ppm(1.15 to 9.2)ppm</td></tr><tr><td><strong>Li</strong></td><td>0.15ppm(0.25 to 5)ppm</td></tr><tr><td><strong>Ca</strong></td><td>3ppm(5 to 100)ppm</td></tr></table>

Repeatability: 1 % CV for 20 consecutive samples

Flame Photometer BZFP-507

Sensitivity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.01ppm</td></tr><tr><td><strong>Na</strong></td><td>0.01ppm</td></tr><tr><td><strong>Li</strong></td><td>0.1ppm</td></tr><tr><td><strong>Ca</strong></td><td>2 ppm</td></tr><tr><td><strong>Ba</strong></td><td>6 ppm</td></tr></table>

Range: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0 to 100 ppm</td></tr><tr><td><strong>Na</strong></td><td>0 to 160 ppm</td></tr><tr><td><strong>Li</strong></td><td>0 to 100 ppm</td></tr><tr><td><strong>Ca</strong></td><td>0 to 1000ppm</td></tr><tr><td><strong>Ba</strong></td><td>0 to 3000 ppm</td></tr></table>

Linearity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.195ppm(0.39 to 3.12)ppm</td></tr><tr><td><strong>Na</strong></td><td>0.69ppm(1.15 to 9.2)ppm</td></tr><tr><td><strong>Li</strong></td><td>0.15ppm(0.25 to 5)ppm</td></tr><tr><td><strong>Ca</strong></td><td>3ppm(5 to100)ppm</td></tr><tr><td><strong>Ba</strong></td><td>9ppm</td></tr></table>

Repeatability: 1 % CV for 20 consecutive samples

Flame Photometer BZFP-501

Range: 0 to 999.9 ppm

Tested elements: K, Na

Channels: 2

LOD: K: 0 to 100 ppm<br> Na: 0 to160 ppm

$3,520.00

Micro-spectrophotometer BZPS-503

Wavelength scanning Range: 190 to 850 nm

Wavelength Accuracy: ±1 nm

Optical Path: 1/0.5/0.05 mm automatic conversion

Optical Range: 190 to 1100 nm

Micro-spectrophotometer BZPS-502

Optical Path: 1/0.5/0.05 mm automatic conversion

Optical Range: 190 to 1100 nm

Sample Volume: 0.3 to 2.0 μl

Light Source: Long-life Xenon lamp

Micro Spectrophotometer BZPS-505

Wavelength Range: 190 to 850 nm

Wavelength Accuracy: ± 1nm

Wavelength Resolution: 2 nm (FWHM at Hg 546 nm)

Repeatability: <± 0.5 nm

Micro Spectrophotometer BZPS-504

Wavelength Range: 190 to 850 nm

Wavelength Accuracy: ± 1 nm

Wavelength Resolution: 2 nm (FWHM at Hg 546 nm)

Repeatability: <± 0.5 nm

Micro Spectrophotometer BZPS-501

Sample Volume: 0.5µl to 2.0µl

Wavelength: 180nm to 910nm; cuvette (OD600):600±8nm

Wavelength Accuracy: ±1 nm

Absorbance Range (equaled 10mm): 0.02 to 300 A; Cuvette (OD600 ):0 to 4A

$5,460.00

NIR Spectrophotometer BZNR-501

Wavelength Range: 900 to 1700 nm

Wavelength  Accuracy: ±1 nm

 Wavelength Reproducibility : ≤1 nm

Wavelength Scanning Interval Absorbance: 1 nm, 4 nm, 8 nm, 16 nm

UV-vis Spectrophotometer BZUS-501

Photometric Accuracy: ±0.002A(0-0.5A),±0.004A (0.5-1A), ±0.3%T (0-100%T)

Wavelength Range: 190 to 1100nm

The Spectral Bandwidth: 2nm

Wavelength Accuracy: ±0.5nm

UV-vis Spectrophotometer BZUS-502

Wavelength Range: 190 to 1100nm

The Spectral Bandwidth: 1.8 nm

Wavelength Accuracy: ±0.1nm,(D2 656.1nm), ±0.3nm All Region

Wavelength Repeatability: ≤0.1nm