Micro Spectrophotometer BZPS-504

Micro Spectrophotometer BZPS-504

Micro Spectrophotometer BZPS-504 works as a new type of full-wavelength spectrophotometer. With the mode of USB output or network transfer data, with an electronic manual. Delivers a wavelength range of 190 to 850nm with a precision of ±1 nm. It uses a liquid column to recognize the irregular function. It results in a light source that is a long-life pulsed xenon flash lamp.

Wavelength Range 190 to 850 nm
Wavelength Accuracy ± 1 nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Repeatability <± 0.5 nm
Light Path 1 mm, 0.05 mm (optical path automatic conversion)
Nucleic Acid measurement range 0.2 to 37500 mg / μl (sa DNA)
Protein measurement range 0.01 to 1120 mg / ml (BSA)
sample volume requirements 0.3 to 2 μl
Absorbance Accuracy 1% (0.76 absorbance at 350 nm)
Absorbance Range 0.002 to 300 Abs (equivalent to 10mm path length)
Sample measurement time less than 3s
Sample base material stainless steel and quartz fiber
Light Source long life pulsed xenon flash lamp
Detector 2048(CMOS) element linear silicide CCD array
  • Users can accept measurement result data and custom methods directly in spreadsheet mode
  • 32GB of storage space is pre-installed
  • Integrated fibre to prevent fibre breakage due to external force collision, which results in hectic measurement results
  • There is no need to warm up, start testing whenever you want
  • Built-in Win10 system, built-in 7-inch high-definition display, full touch operation
  • Stainless steel and quartz fibre used for the platform
  • Using a liquid column to identify abnormal function
  • The built-in Bluetooth and WIFI allow for remote operation and wireless printing of results
  • Two USB ports can be connected to a variety of devices

Nucleic acid, protein, bacteria, cell bacteria, microarray samples, and conventional full-wavelength scanning, among other things, can be detected.

captcha

Reviews

5 ★
100%
4 ★
0%
3 ★
0%
2 ★
0%
1 ★
0%

Submit Your Review

Frequently Asked Questions

NIR Spectrophotometer

NIR Spectrophotometer BZNR-501

  • Wavelength Range : : 900 to 1700 nm
  • Wavelength  Accuracy : : ±1 nm
  •  Wavelength Reproducibility  : : ≤1 nm

Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer BZAAS-501

  • Wavelength Range : : 190 to 900 nm
  • Spectral Bandwidth : : 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic adjustable
  • Wavelength Accuracy : : ≤ 0.15 nm

$15,648.00

Atomic Absorption Spectrophotometer BZAAS-502
  • Wavelength Range  : : 190 to 900 nm
  • Spectral Bandwidth : : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Wavelength Accuracy : : ±0.15 nm

Flame Photometer

Flame Photometer BZFP-501
  • Range : : 0 to 999.9 ppm
  • Tested elements : : K, Na
  • Channels : : 2

$4,224.00

Flame Photometer BZFP-502

  • Range : : <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Li</strong></td><td>optional</td></tr></table>
  • Linearity : : <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.195ppm(0.39 to 3.12)ppm</td></tr><tr><td><strong>Na</strong></td><td>0.69ppm(1.15 to 9.2)ppm</td></tr><tr><td><strong>Li</strong></td><td>optional</td></tr></table>
  • Repeatability : : 1 % CV for 20 consecutive samples

Double Beam Spectrophotometer

Labzee Double Beam Spectrophotometer measures light intensity across different wavelengths to determine absorbance and transmittance. They are equipped with a detector, light source, and monochromator, ensuring accurate and reliable measurements. These spectrophotometer minimizes errors by comparing intensities of sample and reference beams. They feature a touchscreen display for efficient data processing and storage. Our Double Beam Spectrophotometer spans UV, visible, and near-infrared spectra.

Double Beam Spectrophotometer BZSD-501

  • Wavelength Range : : 190 to 1100 nm
  • Spectral Bandwidth : : 0.5, 1.0, 2.0, 4.0 nm
  • Wavelength Accuracy : : ±0.1 nm (D2 656.1 nm), ±0.3 nm full range

$6,660.00

UV/vis spectrophotometer

UV-vis Spectrophotometer BZUS-501
  • Photometric Accuracy : : ±0.002A(0-0.5A),±0.004A (0.5-1A), ±0.3%T (0-100%T)
  • Wavelength Range : : 190 to 1100nm
  • The Spectral Bandwidth : : 2nm
UV-vis Spectrophotometer BZUS-502
  • Wavelength Range : : 190 to 1100nm
  • The Spectral Bandwidth : : 1.8 nm
  • Wavelength Accuracy : : ±0.1nm,(D2 656.1nm), ±0.3nm All Region