Atomic Absorption Spectrophotometer BZAAS-501
Product1
Product2

Atomic Absorption Spectrophotometer BZAAS-501

Atomic Absorption Spectrophotometer BZAAS-501 offers 190 to 900 nm wavelength range and ≤ 0.15 nm accuracy. It uses a built-in double cathode lamp for intense light output and enhanced sensitivity. With flame atomizer concentration of 0.015 µg/mL, it ensures optimal analyte atomization. The adjustable spectral bandwidth from 0.1 to 2.0 nm allows for improved resolution and flexibility. This unit is used in metallurgy, food, pharmaceutical and clinical fields for precise elemental analysis of various samples.

$ 14996

Wavelength Range 190 to 900 nm
Spectral Bandwidth 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic adjustable
Wavelength Accuracy ≤ 0.15 nm
Wavelength Repeatability ± 0.1 nm
Baseline Stability ≤ ± 0.002 A/30 min (static) ≤ ± 0.005A/30 min (dynamic)
Light Source ≤ 6 lamps automatic turret, automatic alignment
Power Source Double cathode power built-in high-performance lamps
Flame Atomizer Characteristic Concentration 0.015 µg/mL/1%
Detection Limit 0.002 µg/mL
Precision RSD ≤ 5 %
Environment Temperature 15℃ to 35℃
Relative Humidity 20 to 80%
Power Requirement 220 V (+5% to -10%), 50/60 Hz; 5000 VA
01 Box Packaging Dimension (L×W×H) 1260 × 640 × 710 mm
02 Box Packaging Dimension (L×W×H) 480 × 390 × 720 mm
03 Box Packaging Dimension (L×W×H) 550 × 550 ×550 mm
01 Box Gross Weight 120 kg
02 Box Gross Weight 26 kg
03 Box Gross Weight 20 kg
Net Weight 166 kg
Hollow cathode lamp × 3
Atomizer × 2
Spare part Carton × 1
Main unit dust cover × 1
3A fuse wire × 1
1.5A fuse wire × 1
Three core power line × 1
Main Unit Signal line × 1
Plastic pipe × 2
Screwdriver × 1
Acetylene hose clip × 3
Acetylene gas pipe: 3 meter
Desktop computer
Printer
Oil-less air compressor
USB and computer access
Titanium metal burner
Automatic ignition
Automatic safety protection
Three light brick configuration
Our Atomic Absorption Spectrophotometer BZAAS-501 is used in environmental testing, chemical, petrochemical, clinical and food industry for highly specific and accurate elemental detection.

NIR Spectrophotometer

NIR Spectrophotometer BZNR-501

  • Wavelength Range : 900 to 1700 nm
  • Wavelength  Accuracy : ±1 nm
  •  Wavelength Reproducibility  : ≤1 nm
Catalog

Micro-Spectrophotometer

Labzee micro-spectrophotometers deliver rapid, accurate quantification of DNA, RNA, and proteins in small-volume samples. They provide optimal performance across molecular biology, genomics, and clinical research. These devices ensure reliability with full-spectrum detection and user-friendly touchscreen control. Their compact design and low sample requirement suit both routine and advanced analyses. Our micro-spectrophotometers are ideal for nucleic acid quantification, purity checks, and micro-volume absorbance measurements.

Micro Spectrophotometer BZPS-501

  • Sample Volume : 0.5µl to 2.0µl
  • Wavelength : 180nm to 910nm; cuvette (OD600):600±8nm
  • Wavelength Accuracy : ±1 nm

$ 7245

Micro Spectrophotometer BZPS-504
  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1 nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
Catalog

Flame Photometer

Labzee Flame Photometers deliver accurate and reliable elemental analysis for sodium, potassium, calcium, and lithium detection. They are designed with advanced flame technology to ensure fast and consistent results for clinical and laboratory applications. Their robust stainless steel build offers durability and resistance to harsh chemicals. They have user-friendly interfaces and digital displays that enables easy operation and real-time monitoring. Our flame photometers enhance lab efficiency with minimal maintenance and high analytical precision.

Flame Photometer BZFP-501
  • Range : 0 to 999.9 ppm
  • Tested elements : K, Na
  • Channels : 2

$ 4848

Flame Photometer BZFP-502

  • Range : <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Li</strong></td><td>optional</td></tr></table>
  • Linearity : <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.195ppm(0.39 to 3.12)ppm</td></tr><tr><td><strong>Na</strong></td><td>0.69ppm(1.15 to 9.2)ppm</td></tr><tr><td><strong>Li</strong></td><td>optional</td></tr></table>
  • Repeatability : 1 % CV for 20 consecutive samples
Catalog

Double Beam Spectrophotometer

Labzee Double Beam Spectrophotometer measures light intensity across different wavelengths to determine absorbance and transmittance. They are equipped with a detector, light source, and monochromator, ensuring accurate and reliable measurements. These spectrophotometer minimizes errors by comparing intensities of sample and reference beams. They feature a touchscreen display for efficient data processing and storage. Our Double Beam Spectrophotometer spans UV, visible, and near-infrared spectra.

Double Beam Spectrophotometer BZSD-501

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 0.5, 1.0, 2.0, 4.0 nm
  • Wavelength Accuracy : ±0.1 nm (D2 656.1 nm), ±0.3 nm full range

$ 13371

UV/Vis Spectrophotometer

UV-vis Spectrophotometer BZUS-501
  • Photometric Accuracy : ±0.002A(0-0.5A),±0.004A (0.5-1A), ±0.3%T (0-100%T)
  • Wavelength Range : 190 to 1100nm
  • The Spectral Bandwidth : 2nm

$ 8717

UV-vis Spectrophotometer BZUS-502
  • Wavelength Range : 190 to 1100nm
  • The Spectral Bandwidth : 1.8 nm
  • Wavelength Accuracy : ±0.1nm,(D2 656.1nm), ±0.3nm All Region

$ 6325