$4,183.00
| Test Elements | K/ Na/ Li/ Ca/ Ba |
| Channel Quantity | 5 |
| Limit Of Detection - K | ≤ 0.156 ppm |
| Limit Of Detection - Na | ≤ 0.184 ppm |
| Limit Of Detection - Li | ≤ 0.1035 ppm |
| Limit Of Detection - Ca | ≤ 2 ppm |
| Limit Of Detection - Ba | ≤ 6.028 ppm |
| Linear Error - K | ≤ 0.195 ppm |
| Linear Error - Na | ≤ 0.69 ppm |
| Linear Error - Li | ≤ 0.1449 ppm |
| Linear Error - Ca | ≤ 3 ppm |
| Linear Error - Ba | ≤ 9.402 ppm |
| Test Range - K | 0.15 to 100 ppm |
| Test Range - Na | 0.18 to 100 ppm |
| Test Range - Li | 0.1 to 30 ppm |
| Test Range - Ca | 0.1 to 1000 ppm |
| Test Range - Ba | 0.1 to 300 ppm |
| Response Time | 8s |
| Sample Uptake | < 3ml/min. |
| Stability | ≤ 3% (15s), ≤15% (6 min.) |
| Reproducibility | ≤ 2% |
| Air Compressor | External |
| Printer | Optional built-in thermal printer |
| Fuel | LPG |
| Power | 30W |
| Voltage | AC 220V ± 10%, 50Hz ± 1Hz |
| Weight | 18 Kg |
| Packaging Dimension | 570 × 530 × 400 mm |
• Atomizer
• Thermal Printer
• Software
• LPG reducing Valve × 1 Piece
• Stainless steel bellows for LPG × 1 Piece
• Silica gel tubing for waste liquid × 1 Piece
• PU tubing for air × 1 Piece
• Air Compressor -1 Piece
The Flame Photometer BZFP-507 is ideal for analyzing essential elements in clinical diagnostics, pharmaceutical quality control, and environmental testing. It supports rapid and accurate detection of minerals in biological fluids, water, soil, and food samples. Its high sensitivity and safety features make it suitable for routine use in labs across healthcare, agriculture, and industry.
Frequently Asked Questions
1: What elements can the BZFP-507 analyze?
The BZFP-507 can simultaneously analyze five elements: Potassium (K), Sodium (Na), Lithium (Li), Calcium (Ca), and Barium (Ba). It uses a 5-channel system that allows multi-element detection in a single run, increasing speed and efficiency in laboratory workflows.
2: How fast is the response time?
The BZFP-507 delivers results quickly, with a response time of 8 seconds. This allows for efficient throughput in both routine and high-volume testing labs.
3: Is the BZFP-507 easy to operate?
Yes, the BZFP-507 features a color touch screen and a user-friendly interface. Its intuitive design makes it easy to operate, even for users with limited technical background, reducing training time and error rates.
4: Does the BZFP-507 have a printing option?
Yes, the device supports an optional built-in thermal printer, allowing users to conveniently print results on-site for documentation and record-keeping.
5: What type of fuel and support equipment are required?
The BZFP-507 operates using LPG (liquefied petroleum gas) as the flame fuel and requires an external air compressor to maintain consistent flame conditions.
6: Which elements can be measured with a flame photometer?
Most flame photometers can measure Sodium (Na), Potassium (K), Calcium (Ca), and Lithium (Li). Some advanced models may also detect Barium (Ba) and Strontium (Sr).
7: How does a flame photometer work?
It works by introducing a sample solution into a flame, which excites the electrons of metal ions. As these electrons return to their ground state, they emit light at characteristic wavelengths. The instrument measures this light intensity to determine ion concentration.
8: Is calibration necessary for flame photometry?
Yes, flame photometers must be calibrated with standard solutions before each use to ensure accurate and reliable results. Calibration corrects for variations in flame conditions, instrument sensitivity, and sample composition.