Micro Spectrophotometer BZPS-505 works as a new type of full-wavelength spectrophotometer. With a mode of USB output or network transfer data, having an electronic manual. It comes with a light source, a long-life pulsed xenon flash lamp. With a pre-installation storage spacing of 32 GB. At a minimum, the sample volume of the cuvette is 20 l, with a wavelength range of 190 to 850 nm. 

Wavelength Range 190 to 850 nm
Wavelength Accuracy ± 1nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Repeatability <± 0.5 nm
Light Path 1 mm, 0.05 mm (optical path automatic conversion)
Absorbance Accuracy 1% (0.76 absorbance at 350 nm)
Absorbance Range 0.002 to 300Abs (equivalent to 10mm path length)
sample volume Requirements 0.3 to 2 μl
Cuvette Specifications 1 mm, 2 mm, 5 mm, 10 mm
Min sample volume of the cuvette 20 μl
The minimum height of the cuvette sample 5 mm
Temperature Control 4 to 42 ℃ thermostat adjustable temperature error <± 0.5 ℃
Nucleic Acid measurement range 0.2 to 37500 mg / μl (sa DNA)
Protein measurement range 0.01 to 1120 mg / ml (BSA)
Sample measurement time less than 3s
Sample base material stainless steel and quartz fiber
Light Source long life pulsed xenon flash lamp
Detector 2048(CMOS) element linear silicide CCD array
  • Users can save measurement result data and custom methods directly in spreadsheet mode
  • 32GB of storage space is pre-installed
  • Integrated fiber to prevent fibre breakage due to external force collision, which results in chaotic measurement results
  • There is no need to warm up, start testing whenever you want
  • Built-in Win10 system, built-in 7-inch high-definition display, full touch operation
  • Stainless steel and quartz fiber is used for the platform
  • Using a liquid column to identify abnormal function
  • The built-in Bluetooth and WIFI allow for remote operation and wireless printing of results
  • Two USB ports that can connect to a variety of devices such as mice, keyboards, desktop computers, and so on

Nucleic acid, protein, bacteria, cell bacteria, microarray samples, and conventional full-wavelength scanning, among other things, can be detected.

captcha

Reviews

5 ★
100%
4 ★
0%
3 ★
0%
2 ★
0%
1 ★
0%

Submit Your Review

Frequently Asked Questions

NIR Spectrophotometer

NIR Spectrophotometer BZNR-501

  • Wavelength Range : : 900 to 1700 nm
  • Wavelength  Accuracy : : ±1 nm
  •  Wavelength Reproducibility  : : ≤1 nm
Catalog

Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer BZAAS-501

  • Wavelength Range : : 190 to 900 nm
  • Spectral Bandwidth : : 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic adjustable
  • Wavelength Accuracy : : ≤ 0.15 nm
Catalog
Atomic Absorption Spectrophotometer BZAAS-502
  • Wavelength Range  : : 190 to 900 nm
  • Spectral Bandwidth : : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Wavelength Accuracy : : ±0.15 nm
Catalog

Flame Photometer

Flame Photometer BZFP-501
  • Range : : 0 to 999.9 ppm
  • Tested elements : : K, Na
  • Channels : : 2
Catalog

Flame Photometer BZFP-502

  • Range : : <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Li</strong></td><td>optional</td></tr></table>
  • Linearity : : <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.195ppm(0.39 to 3.12)ppm</td></tr><tr><td><strong>Na</strong></td><td>0.69ppm(1.15 to 9.2)ppm</td></tr><tr><td><strong>Li</strong></td><td>optional</td></tr></table>
  • Repeatability : : 1 % CV for 20 consecutive samples
Catalog

Double Beam Spectrophotometer

Labzee Double Beam Spectrophotometer measures light intensity across different wavelengths to determine absorbance and transmittance. They are equipped with a detector, light source, and monochromator, ensuring accurate and reliable measurements. These spectrophotometer minimizes errors by comparing intensities of sample and reference beams. They feature a touchscreen display for efficient data processing and storage. Our Double Beam Spectrophotometer spans UV, visible, and near-infrared spectra.

Double Beam Spectrophotometer BZSD-501

  • Wavelength Range : : 190 to 1100 nm
  • Spectral Bandwidth : : 0.5, 1.0, 2.0, 4.0 nm
  • Wavelength Accuracy : : ±0.1 nm (D2 656.1 nm), ±0.3 nm full range
Catalog

UV/Vis Spectrophotometer

UV-vis Spectrophotometer BZUS-501
  • Photometric Accuracy : : ±0.002A(0-0.5A),±0.004A (0.5-1A), ±0.3%T (0-100%T)
  • Wavelength Range : : 190 to 1100nm
  • The Spectral Bandwidth : : 2nm
Catalog
UV-vis Spectrophotometer BZUS-502
  • Wavelength Range : : 190 to 1100nm
  • The Spectral Bandwidth : : 1.8 nm
  • Wavelength Accuracy : : ±0.1nm,(D2 656.1nm), ±0.3nm All Region
Catalog