UV-vis Spectrophotometer BZUS-501

UV-vis Spectrophotometer BZUS-501

UV-vis Spectrophotometer BZUS-501 is a quasi-double beam optical system with automatic wavelength calibration and automatic deviation repair. It has a wavelength range of 190 to 1100nm with a spectral bandwidth of 2nm. Equipped with a 7-inch large screen dot-matrix liquid crystal, clear map data display, friendly interface, easy to operate, and can independently complete testing functions. It is designed with all types of speed variable scanning.

Photometric Accuracy ±0.002A(0-0.5A),±0.004A (0.5-1A), ±0.3%T (0-100%T)
Wavelength Range 190 to 1100nm
The Spectral Bandwidth 2nm
Wavelength Accuracy ±0.5nm
Wavelength Repeatability ≤0.2nm
Photometric Repeatability ±0.002A(0-0.5A),±0.004A (0.5-1A), ±0.3%T (0-100%T)
Stray Light ±0.002A(0-0.5A),±0.004A (0.5-1A), ±0.3%T (0-100%T)
Baseline Drift (Stability) ≤0.05%T (220/360nm)
Baseline Flatness ≤0.001A/h(500nm, 0A)
Noise Level ±0.0015A
Luminosity Range ±0.1%T(0%T), ±0.3%T(100%T), ±0.0005A (500nm)
Wavelength Setting Mode to 200%T, -0.3 to 3A, 0 to 9999C, 0 to 9999F
Scanning Speed Automatic, wavelength resolution 0.1nm
PC Software High, medium and low are available
Data Output PC scan analysis software (standard)
Printout USB
Display System Parallel port
The Light Source 7 inch 320×240, large screen LCD
The Detector Original imported tungsten lamp, xenon lamp
The Power Supply Imported silicon photodiode
Overall Dimensions AC 220V/50Hz or110V/60Hz
Weight 625×430×210mm
  • It is a standalone double-beam, double-optical-path optical system</br> Both wavelength calibration and deviation repair are automatic</br> 5-100 mm vials can fit in the comfortable random sample</br> With 24-bit high-speed A/D conversion, the instrument is precise and sensitive</br> It can independently carry out photometric measurement, quantitativemeasurement, spectral scanning, kinetics, and DNA/protein testing tasks</br> There is also a suspension optical system</br> The thickened bottom plate eliminates the impact of vibration or deformation on the optical system</br> It fully complies with pharmacopeia requirements with its narrower frequency range and better resolution</br> The design of the device encompasses a substantial dot matrix crystal display (LCD display, clear map data display, a user-friendly interface, and simple operation</br> It has a deuterium lamp with a flange seat that is long-lasting and environmentally friendly. Optical debugging is not required for light replacement</br> The graph and data can be saved in real-time and kept even without power</br> It can be exported to a PC and printed

It is widely used in life science, medical science, environmental science, agricultural science, metrology science, food science, geological science, petroleum science, medical and health care, iron and steel metallurgy, chemistry and chemical industry, and other fields.

captcha

Reviews

5 ★
100%
4 ★
0%
3 ★
0%
2 ★
0%
1 ★
0%

Submit Your Review

Frequently Asked Questions

NIR Spectrophotometer

NIR Spectrophotometer BZNR-501

  • Wavelength Range : : 900 to 1700 nm
  • Wavelength  Accuracy : : ±1 nm
  •  Wavelength Reproducibility  : : ≤1 nm

Micro Spectrophotometer

Micro Spectrophotometer BZPS-501

  • Sample Volume : : 0.5µl to 2.0µl
  • Wavelength : : 180nm to 910nm; cuvette (OD600):600±8nm
  • Wavelength Accuracy : : ±1 nm

$6,552.00

Micro Spectrophotometer BZPS-504
  • Wavelength Range : : 190 to 850 nm
  • Wavelength Accuracy : : ± 1 nm
  • Wavelength Resolution : : 2 nm (FWHM at Hg 546 nm)

Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer BZAAS-501
  • Wavelength Range : : 190 to 900 nm
  • Spectral Bandwidth : : 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic adjustable
  • Wavelength Accuracy : : ≤ 0.15 nm

$15,648.00

Atomic Absorption Spectrophotometer BZAAS-502

  • Wavelength Range  : : 190 to 900 nm
  • Spectral Bandwidth : : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Wavelength Accuracy : : ±0.15 nm

Flame Photometer

Flame Photometer BZFP-501

  • Range : : 0 to 999.9 ppm
  • Tested elements : : K, Na
  • Channels : : 2

$4,224.00

Flame Photometer BZFP-502
  • Range : : <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Li</strong></td><td>optional</td></tr></table>
  • Linearity : : <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.195ppm(0.39 to 3.12)ppm</td></tr><tr><td><strong>Na</strong></td><td>0.69ppm(1.15 to 9.2)ppm</td></tr><tr><td><strong>Li</strong></td><td>optional</td></tr></table>
  • Repeatability : : 1 % CV for 20 consecutive samples

Double Beam Spectrophotometer

Labzee Double Beam Spectrophotometer measures light intensity across different wavelengths to determine absorbance and transmittance. They are equipped with a detector, light source, and monochromator, ensuring accurate and reliable measurements. These spectrophotometer minimizes errors by comparing intensities of sample and reference beams. They feature a touchscreen display for efficient data processing and storage. Our Double Beam Spectrophotometer spans UV, visible, and near-infrared spectra.

Double Beam Spectrophotometer BZSD-501
  • Wavelength Range : : 190 to 1100 nm
  • Spectral Bandwidth : : 0.5, 1.0, 2.0, 4.0 nm
  • Wavelength Accuracy : : ±0.1 nm (D2 656.1 nm), ±0.3 nm full range

$6,660.00