Micro-spectrophotometer BZPS-502

Micro-spectrophotometer BZPS-502

Micro-spectrophotometer BZPS-502 is an innovative variety of full-wavelength spectrophotometers used for sample detection. It has a built-in Bluetooth and Wi-Fi module that enables remote operation and wireless printing of results. It is made of stainless steel and quartz fiber. It has an optical path of 1/0.5/0.05 mm with a required operating wavelength range of 190 to 850 nm.

Optical Path 1/0.5/0.05 mm automatic conversion
Optical Range 190 to 1100 nm
Sample Volume 0.3 to 2.0 μl
Light Source Long-life Xenon lamp
Detector 3864 linear CCD array
Wavelength scanning Range 190 to 850 nm
Wavelength Accuracy ±1 nm
Wavelength Resolution 2 nm (FWHM Hg 546 nm)
Absorbance Accuracy 0.002 Abs
Absorbance Range 1% (0.76 absorbances at 350 nm)
Nucleic acid Range 0.002 to 300 Abs (equivalent to 10mm optical path)
Protein Range 0.4 to 15000 ng/μl (ds-DNA)
Detection Time 0.01 to 400 mg/ml (BSA)
Machine Size less than 3s
Weight 20×30×20 cm
  • There is no need to warm up; checking can begin at any time
  • Instrument control and operation; built-in Win10 system; constructed 7-inch high-definition showcase; full touch operation
  • 32GB of storage space is pre-installed
  • Two USB ports can be connected to a variety of devices
  • The platform is constructed out of stainless steel and quartz fiber
  • Built-in fiber to prevent fiber breakage caused by external force collision, resulting in chaotic measurement results
  • Built-in Bluetooth and WIFI allow for remote operation and wireless printing of results
  • Users can save measuring device result data and design techniques straight in spreadsheet mode with a digital manual

Applicable for detecting nucleic acid, protein, colloidal, and proteomic samples, as well as conventional full-wavelength scanning, among other things.

captcha

Reviews

5 ★
100%
4 ★
0%
3 ★
0%
2 ★
0%
1 ★
0%

Submit Your Review

Frequently Asked Questions

NIR Spectrophotometer

NIR Spectrophotometer BZNR-501

  • Wavelength Range : : 900 to 1700 nm
  • Wavelength  Accuracy : : ±1 nm
  •  Wavelength Reproducibility  : : ≤1 nm

Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer BZAAS-501

  • Wavelength Range : : 190 to 900 nm
  • Spectral Bandwidth : : 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic adjustable
  • Wavelength Accuracy : : ≤ 0.15 nm

$15,648.00

Atomic Absorption Spectrophotometer BZAAS-502
  • Wavelength Range  : : 190 to 900 nm
  • Spectral Bandwidth : : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Wavelength Accuracy : : ±0.15 nm

Flame Photometer

Flame Photometer BZFP-501
  • Range : : 0 to 999.9 ppm
  • Tested elements : : K, Na
  • Channels : : 2

$4,224.00

Flame Photometer BZFP-502

  • Range : : <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Li</strong></td><td>optional</td></tr></table>
  • Linearity : : <table class='table table-striped table-bordered table-responsive'><tr><td><strong>K</strong></td><td>0.195ppm(0.39 to 3.12)ppm</td></tr><tr><td><strong>Na</strong></td><td>0.69ppm(1.15 to 9.2)ppm</td></tr><tr><td><strong>Li</strong></td><td>optional</td></tr></table>
  • Repeatability : : 1 % CV for 20 consecutive samples

Double Beam Spectrophotometer

Labzee Double Beam Spectrophotometer measures light intensity across different wavelengths to determine absorbance and transmittance. They are equipped with a detector, light source, and monochromator, ensuring accurate and reliable measurements. These spectrophotometer minimizes errors by comparing intensities of sample and reference beams. They feature a touchscreen display for efficient data processing and storage. Our Double Beam Spectrophotometer spans UV, visible, and near-infrared spectra.

Double Beam Spectrophotometer BZSD-501

  • Wavelength Range : : 190 to 1100 nm
  • Spectral Bandwidth : : 0.5, 1.0, 2.0, 4.0 nm
  • Wavelength Accuracy : : ±0.1 nm (D2 656.1 nm), ±0.3 nm full range

$6,660.00

UV/vis spectrophotometer

UV-vis Spectrophotometer BZUS-501
  • Photometric Accuracy : : ±0.002A(0-0.5A),±0.004A (0.5-1A), ±0.3%T (0-100%T)
  • Wavelength Range : : 190 to 1100nm
  • The Spectral Bandwidth : : 2nm
UV-vis Spectrophotometer BZUS-502
  • Wavelength Range : : 190 to 1100nm
  • The Spectral Bandwidth : : 1.8 nm
  • Wavelength Accuracy : : ±0.1nm,(D2 656.1nm), ±0.3nm All Region