Double Basket Tissue Processor BZDTP-501
Product1
Product2

Double Basket Tissue Processor BZDTP-501

Labzee Double Basket Tissue Processor BZDTP-501 built for high‑throughput tissue preparation, processing about 200 tissues per run (100 per basket). It performs automated dehydration, clearing, and paraffin infiltration with 14 reagent containers of 2000 ml each. Its dual‑basket design allows independent basket control for workflow flexibility, while touch screen display with intelligent key operation provides simple control and monitoring for processing more daily batch volumes.

$ 9212

Reagent Container Capacity 2000 ml
No. of Reagent Containers 14 pieces
Processing Time per Container 0-99 hours adjustable
No. of Dehydrated Tissues About 200 pcs (100 pcs per basket)
Hanging Basket Filtrate Time can be adjusted arbitrarily
Power Consumption 500 W
Product Dimension 1300 × 600 × 600 mm
Package Dimension 1380 × 680 × 740 mm
Net Weight 116 Kg
Gross Weight 173 Kg
Packaging Type Wooden Case

Dual Basket: Two baskets process multiple tissue batches at the same time. 
Touch Screen: Large color display for simple monitoring and protocol setting. 
Adjustable Processing Time: Flexible timing for different tissue types. 
High Reagent Capacity: Multiple containers for long cycles, fewer refills. 
Independent Basket Control: Run different protocols on each basket simultaneously.

• Clinical Diagnostics Industry: Used for high‑volume processing of surgical specimens and biopsies in pathology labs. 
• Histology Labs: Applied for processing large tissue batches with dual baskets for faster turnaround. 
• Pharmaceutical Research: Designed for running different protocols on separate baskets for drug safety studies. 
• Academic Research Labs: Suitable for overnight processing of research tissue samples with adjustable timing. 
• Embedding & Pathology: Intended for dehydration, clearing, and paraffin infiltration prior to microtomy.

Frequently Asked Questions

1: What is the reagent container capacity of the Double Basket Tissue Processor BZDTP-501?

The Double Basket Tissue Processor BZDTP-501 features reagent containers each with a capacity of 2000 ml. This large volume supports extended processing cycles and reduces the need for frequent reagent replacement, enhancing overall efficiency in the laboratory.

2: How many reagent containers can the Double Basket Tissue Processor BZDTP-501 hold, and why is this important?

It accommodates 14 reagent containers, which allows laboratories to run complex tissue processing protocols using multiple reagents in one automated cycle, improving workflow versatility and saving time.

3: Is it possible to adjust the processing time on the Double Basket Tissue Processor BZDTP-501? If so, what is the time range?

Yes, the processing time on the Double Basket Tissue Processor BZDTP-501 is fully adjustable from 0 to 99 hours per container. This feature offers laboratories the flexibility to tailor the tissue processing according to the sample requirements.

4: How many tissue samples can the Double Basket

Tissue Processor BZDTP-501 process simultaneously? This device is capable of processing about 200 dehydrated tissue samples at once, divided equally between its two baskets, which significantly increases sample throughput and lab productivity.

5: What electrical specifications and physical size does the Double Basket Tissue Processor BZDTP-501 have?

The Double Basket Tissue Processor BZDTP-501 operates on an AC 220V ±10% power supply with 50 Hz frequency. Its compact dimensions allow it to fit comfortably within most laboratory spaces while maintaining a sturdy construction for reliable operation.

6: When should a Double Basket Tissue Processor be used?

A Double Basket processor is ideal when large sample volumes need processing in limited time. It allows parallel processing of different batches or protocols. This improves efficiency in high-demand labs.

7: Can two different protocols be run simultaneously?

Yes, many Double Basket models allow independent programming for each basket. This helps process different tissue types or urgent samples in parallel. Always check model-specific capabilities for protocol customization.

8: Can the baskets be loaded while the unit is running?

No, for safety and to maintain protocol integrity, baskets should only be loaded when idle. Opening during operation may interrupt cycles or expose reagents. Always wait for completion and follow proper procedures.

9: When is cleaning or maintenance required?

Routine cleaning is recommended after each full cycle or daily use. Scheduled maintenance depends on usage frequency and reagent type. Proper upkeep ensures consistent results and longer system life.

10: Can it be used for overnight processing?

Yes, these processors are often designed for overnight runs with automated control. Safety systems monitor temperature and reagent levels during unattended use. Ensure all parameters are correctly set before initiating long cycles.


Double Basket Tissue Processor BZDTP-501

Double Basket Tissue Processor BZDTP-501

Enclosed Tissue Processor

Labzee Enclosed Tissue Processors designed for safe, contamination-free tissue processing in histology labs. They perform fully enclosed dehydration, clearing, and paraffin infiltration – minimizing exposure to harmful reagents and protecting specimen integrity. Touch-screen controls and integrated safety protocols enhance user protection. Our range includes models with reagent bottle capacities from 2.3L to 4.8L, retort volumes from 3.8L to 6.8L, and wax cylinder volumes from 2.6L to 5.5L (30–65°C). Customizable programs, large sample capacities, and advanced reagent handling support high-volume workflows.

Enclosed Tissue Processor BZCTP-501

  • Reagent Bottle Capacity : 2.3 L
  • Retort Volume : 3.8 L
  • Wax Cylinder Volume : 2.6 L

$ 17618

Enclosed Tissue Processor BZCTP-502

  • Reagent Bottle Capacity : 3.2 L
  • Retort Volume : 5.3 L
  • Wax Cylinder Volume : 4.3 L

$ 16560

Spin Tissue Processor

Labzee Spin Tissue Processors designed for rapid and uniform processing of biological tissue samples using centrifugal motion. They combine precise reagent delivery with controlled spinning action to accelerate dehydration, clearing, and paraffin infiltration. Our rotary tissue processors support multiple sample baskets, customizable protocols, and efficient reagent usage to enhance throughput. Their spinning mechanism improves reagent penetration and reduces processing time – faster results without damaging tissue integrity while increasing daily sample volume and reducing operator effort.

Spin Tissue Processor BZSTP-502
  • Number of Processing Steps : 12 Steps
  • Temperature Range : 60 - 99℃
  • Ambient Temperature : +5℃ - 40℃

$ 6647

Spin Vacuum Tissue Processor BZSTP-501
  • Station Type : Carousel
  • Number of Stations : 12
  • Vacuum Pressure : Max 0.05 MPa (~0.5 bar)

$ 7441

Automatic Tissue Processor

Labzee Automatic Tissue Processors are designed to streamline and standardize histology tissue preparation with minimal manual intervention. Our range includes models with single cylinder/tank capacities from 1000ml to 2200ml and specimen capacity per basket from 60 to 125 specimens. They perform sequential dehydration, clearing, and paraffin infiltration through fully programmable cycles, allowing adjustment of duration, reagent type, and temperature for different tissue protocols. Intuitive interfaces, enclosed chambers, and built-in safety controls enhance operational efficiency and laboratory safety – high throughput, consistent outcomes, and safe unattended operation.

Automatic Tissue Processor BZUTP-501

  • No. of Liquid Cylinders : 12 pcs (including 3 wax cylinders)
  • Single Cylinder Volume : 2200 ml
  • Specimen Capacity per Basket : 125 specimens

$ 5550

Automatic Tissue Processor BZUTP-502

  • No. of Tanks : 12 pcs (including 3 wax tanks at the end)
  • Single Tank Capacity : 1500 ml
  • Specimen Capacity per Basket : 75 specimens

$ 4975