Automatic Tissue Processor BZUTP-503
Product1
Product2
Product3

Automatic Tissue Processor BZUTP-503

Labzee Automatic Tissue Processor BZUTP-503 offers a compact benchtop unit for routine tissue sample processing. It handles up to 60 specimens per basket with 12 tanks of 1000 ml each for complete dehydration, clearing, and wax infiltration. Adjustable processing time and stirring frequency allow flexibility for different tissue protocols, while its power failure protection keeps the unit running for 4 to 6 hours during a power cut.

$ 4791

No. of Tanks 12 pcs (including 3 wax tanks at the end)
Single Tank Capacity 1000 ml
Specimen Capacity per Basket 60 specimens
Processing Time per Tank 0-99 hours (arbitrarily set)
Cylinder Start Dwell Time 45-100 seconds
Stirring Frequency 0-5 times/min (arbitrarily set; 3 best)
Power Consumption ≤500 W
Product Dimension 1010 × 390 × 450 mm
Package Dimension 1140 × 560 × 580 mm
Net Weight 60 Kg
Gross Weight 85 Kg
Packaging Type Wooden Case

1. Extra Tank 

2. Tissue Basket 

1. Reagent bottle × 9 Pieces

2. Tissue Basket × 1 Piece

3. The Exhaust Pipe × 1 Piece

4. Tissue Cassette × 20 Pieces

5. Fuse(5A) × 2 Pieces

6. Power Line × 1 Line

Multiple Tank Setup: Multiple tanks including wax tanks for complete tissue processing in one run. 
Tissue Protection Cylinder: Dedicated cylinder safeguards sample integrity during processing. 
Real‑Time Display: Shows program content and operating status throughout sampling. 
Power Failure Protection: Keeps the unit running during a power cut – prevents sample loss. 
Compact Benchtop Design: Small footprint automates histology workflows.

• Histopathology Labs: Used for routine tissue dehydration and processing for diagnostic microscopy. 
• Clinical Diagnostics: Applied for processing surgical specimens and biopsies in moderate‑volume labs. 
• Research Projects: Designed for reproducible tissue preparation in biomedical and pharmaceutical studies. 
• Teaching & Training Labs: Suitable for demonstrating standard histology techniques to students. 
• Routine Histology Workflows: Intended for labs needing consistent, unattended tissue processing with power failure protection.

Frequently Asked Questions

1: How many tanks does the Automatic Tissue Processor BZUTP-503 have and what is their capacity?

The Automatic Tissue Processor BZUTP-503 is equipped with 12 tanks, each holding 1000 ml. This setup includes 3 wax tanks for comprehensive tissue processing needs.

2: What is the specimen capacity per basket in this tissue processor?

It can process up to 60 specimens per basket, allowing efficient handling of moderate sample volumes.

3: Can the processing time per tank be adjusted?

Yes, the processing time is arbitrarily adjustable from 0 to 99 hours per tank, providing flexibility for various tissue protocols.

4: What is the function of the stirring frequency in the Automatic Tissue Processor BZUTP-503?

The stirring frequency, which can be set between 0 to 5 times per minute (with 3 times per minute recommended), ensures even reagent distribution and improved tissue processing quality.

5: What are the size and power requirements of the Automatic Tissue Processor BZUTP-503?

This device operates on AC 220V ±10% at 50 Hz with a power consumption of ?500 W. Its compact dimensions allow it to fit comfortably in standard laboratory spaces.

6: When should an Automatic Tissue Processor be

preferred over manual methods? Automatic processors save time, reduce human error, and deliver consistent results. They are best used in labs with moderate to high sample volumes. They improve efficiency in routine histological workflows.

7: Can the processor be customized for specific tissue protocols?

Yes, Automatic Tissue Processors allow full customization of processing cycles. Parameters like duration, reagent type, and temperature can be adjusted. This flexibility supports various tissue types and lab standards.

8: Can it run unattended during overnight shifts?

Yes, these units are designed for safe, unattended operation with automated monitoring. Built-in alarms and safety shutdowns ensure reliability during long runs. Always verify settings before leaving the unit running.

9: When does the system need maintenance?

Basic cleaning should be done after each run to avoid residue buildup. Full maintenance depends on usage frequency and manufacturer guidelines. Regular upkeep ensures processing accuracy and equipment longevity.

10: Can different sample batches be processed on the same day?

Yes, multiple batches can be processed by programming new cycles after completion. Efficient scheduling helps maximize daily throughput. Ensure reagent levels and temperatures are properly maintained between runs.


Automatic Tissue Processor BZUTP-503

Automatic Tissue Processor BZUTP-503

Enclosed Tissue Processor

Labzee Enclosed Tissue Processors designed for safe, contamination-free tissue processing in histology labs. They perform fully enclosed dehydration, clearing, and paraffin infiltration – minimizing exposure to harmful reagents and protecting specimen integrity. Touch-screen controls and integrated safety protocols enhance user protection. Our range includes models with reagent bottle capacities from 2.3L to 4.8L, retort volumes from 3.8L to 6.8L, and wax cylinder volumes from 2.6L to 5.5L (30–65°C). Customizable programs, large sample capacities, and advanced reagent handling support high-volume workflows.

Enclosed Tissue Processor BZCTP-501

  • Reagent Bottle Capacity : 2.3 L
  • Retort Volume : 3.8 L
  • Wax Cylinder Volume : 2.6 L

$ 17618

Enclosed Tissue Processor BZCTP-502

  • Reagent Bottle Capacity : 3.2 L
  • Retort Volume : 5.3 L
  • Wax Cylinder Volume : 4.3 L

$ 16560

Spin Tissue Processor

Labzee Spin Tissue Processors designed for rapid and uniform processing of biological tissue samples using centrifugal motion. They combine precise reagent delivery with controlled spinning action to accelerate dehydration, clearing, and paraffin infiltration. Our rotary tissue processors support multiple sample baskets, customizable protocols, and efficient reagent usage to enhance throughput. Their spinning mechanism improves reagent penetration and reduces processing time – faster results without damaging tissue integrity while increasing daily sample volume and reducing operator effort.

Spin Tissue Processor BZSTP-502
  • Number of Processing Steps : 12 Steps
  • Temperature Range : 60 - 99℃
  • Ambient Temperature : +5℃ - 40℃

$ 6647

Spin Vacuum Tissue Processor BZSTP-501
  • Station Type : Carousel
  • Number of Stations : 12
  • Vacuum Pressure : Max 0.05 MPa (~0.5 bar)

$ 7441

Double Basket Tissue Processor

Labzee Double Basket Tissue Processors are built for high-throughput tissue preparation, allowing simultaneous processing of two sample batches. They perform efficient automated dehydration, clearing, and paraffin infiltration with precision and speed. Our Tissue Processors accommodate large sample volumes with programmable cycles and independent basket control for workflow flexibility. Their dual-chamber design, touchscreen interface, and safety monitoring support busy laboratory settings and high-demand histology workflows – process more samples per day with less hands-on time.

Double Basket Tissue Processor BZDTP-501

  • Reagent Container Capacity : 2000 ml
  • No. of Reagent Containers : 14 pieces
  • Processing Time per Container : 0-99 hours adjustable

$ 9212