Microplate Reader BZMPR-501

Microplate Reader BZMPR-501

Labzee Microplate Reader BZMPR-501 reads 96- or 48-well microplates using a silicon photodiode detector across a 400–800 nm wavelength range. It measures absorbance from 0.000 to 4.000 A with ±0.008 A accuracy and 0.001 A resolution, supporting precise optical density readings. A controlled tungsten halogen lamp or LED light source provides illumination for optical measurements. Reading speed is ≤10 seconds for single-wavelength and ≤20 seconds for double-wavelength measurements, with built-in linear shaking at 3 selectable speeds for sample mixing before measurement.

$ 3077

Input ELISA reader software
Microplate Types 96/ 48-well plate
Photodetector Silicon photodiode
Light Source 8V/50W controlled tungsten halogen lamp or LED light
Wavelength Range 400–800 nm (Halogen Lamp); 400–725 nm (LED)
Standard Filters 405, 450, 492, 630 nm + 1 Optional
Reading Range 0.000–4.000 A
Resolution 0.001 A
Accuracy ±0.008 A
Reproducibility ≤0.2%
Stability ±0.003 A
Shaking Linear Shaking, 3 Speeds
Reading Speed Single Wavelength ≤10 s; Double Wavelength ≤20 s
Interface Connections 2 × USB-A, 1 × USB-B, 1 × RS-232, 1 × Printer
Printer Built-in Thermal Printer; Optional External Printer
Power Supply 100–240 V, 50–60 Hz
Dimensions (W × D × H) 475 × 350 × 210 mm
Shipping Size (W × D × H) 620 × 480 × 380 mm
Net / Gross Weight 9 / 13 kg

Optional Filter: 562 nm

• Fast Readout: Provides rapid readings for absorbance, transmission, concentration, and qualitative studies, with self-diagnostic and alarm functions.
• 7-Inch Capacitive Touch Screen: Allows standalone operation or connection to a PC for instrument control.
• Flexible Board Layout: Displays blank, standard, sample, reference, and QC settings on one screen.
• Four-Position Filter Mounting: Accommodates 405, 450, 492, and 630 nm filters with one additional filter position.
• Multiple Report Formats: Provides more than 20 report formats for different data presentation requirements.
• Data Evaluation: Supports qualitative and quantitative evaluation with cut-offs, curve fitting, and conversion formulas.
• Eight-Channel Optics: Provides multi-channel optical detection for fast microplate readout.
• Automatic Light Tuning and Calibration: Automatically adjusts light intensity and performs calibration for measurements.
• Reference Channel: Provides optimized light intensity for consistent optical measurement conditions.

• ELISA Testing: Measures optical density of samples in ELISA microplate assays.
• Clinical Diagnostics: Performs absorbance measurements for microplate-based diagnostic testing.
• Pharmaceutical Research: Measures absorbance in microplate-based pharmaceutical assays.
• Biotechnology Research: Evaluates absorbance data from quantitative and qualitative microplate assays.
• Biological Research: Measures optical density in laboratory microplate-based biological assays.

Frequently Asked Questions

1: What types of microplates are compatible with the BZMPR-501?

The BZMPR-501 supports both 96-well and 48-well microplates.

2: Can the BZMPR-501 handle high-throughput screening?

Yes, BZMPR-501 support for 96-well plates and rapid optical reading makes it suitable for high-throughput assays.

3: Does the BZMPR-501 come with built-in shaking functionality for assay mixing?

Yes, BZMPR-501 offers linear shaking at three selectable speeds to improve assay consistency and mixing.

4: Can the BZMPR-501 be integrated with LIMS or external systems?

While the main connection is via USB, data from the ELISA software can be exported and used in compatible systems.

5: Can the BZMPR-501 be used in clinical diagnostics?

Yes, the high accuracy, reproducibility, and stability make it suitable for clinical diagnostic applications requiring precise absorbance readings.

6: What is a microplate reader and what is it used for?

A microplate reader is a laboratory instrument used to detect biological, chemical, or physical events in samples contained in microplates, commonly used for ELISA, absorbance, fluorescence, and luminescence assays.

7: Can one microplate reader support multiple assay types?

Yes, multimode microplate readers can handle various assays by combining multiple detection technologies in a single device.

8: What is the read speed and sensitivity of the instrument?

Read speeds vary from a few seconds per plate to less than 30 seconds for full plates. Sensitivity depends on the detection mode and optical system.


Moisture Analyzer

Labzee Moisture Analyzers offer accurate and reliable moisture content measurement for industries like food, pharmaceuticals, and chemicals. They use advanced halogen heating technology for fast and precise results. These analyzers are built to be compact, durable, and suitable for daily use with consistent performance. Our moisture analyzers are helpful for quality control, compliance, and research, ensuring efficient processes and accurate results.

Halogen Moisture Analyzer BZMA-501

  • Capacity : 110g
  • Operating Temperature : 5˚C to 35˚C
  • Readability : 0.01g

$ 2100

Halogen Moisture Analyzer BZMA-502

  • Capacity : 110g
  • Operating Temperature : 5°C to 35°C
  • Readability : 0.001g

$ 2008

ELISA Analyzer

Labzee ELISA Analyzers are designed to detect and quantify biological molecules such as proteins, hormones and antibodies within a sample. Our ELISA Analyzers are optimized to detect even the minute quantities of analytes. These Analyzers have flexible plate formats that is it can read different plate formats such as 96 or 384 well plates. Our ELISA Analyzers detect and quantify disease biomarkers, including those for infectious diseases, autoimmune disorders, cancers, and hormone levels, aiding in diagnosis and treatment monitoring.

ELISA Analyzer BZEA-501
  • Measurement Module : Photometric microplate reader module
  • Measurement System : 8-channel
  • Detector : Silicon Photodiodes

$ 19182