$ 6530
| Applicable Number Of Users | 1 |
| Cleanliness Class | 100 |
| Inflow Air Velocity | 0.55 m/s |
| Down Airflow Velocity | 0.35 m/s |
| Noise | ≤ 67 dB |
| Vibrational Half Peak Value | ≤ 5 µm |
| Illuminance | ≥ 650 Lux |
| Ambient Temperature | 10 to 30°C |
| Relative Humidity at 25°C | ≤ 70 % |
| Atmospheric Pressure | 80 to 105 Pa |
| Height of Rack | 630 mm |
| Power | 1800 W |
| Power And Number Of Lamp | 20 W, 1 Piece |
| Power And Number Of UV Light | 20 W, 1 Piece |
| Net Weight | 198 Kg |
| Gross Weight | 236 Kg |
| Internal Dimension | 1060 × 580 × 595 mm |
| Housing Dimension | 1200 × 770 × 2320 mm |
| Inflow HEPA Dimension | 1095 × 475 × 70 mm |
| Exhaust HEPA Dimension | 500 × 460 × 70 mm |
| Packaging Dimension | 1460 × 970 × 1880 mm |
• Intelligent Control Display: Shows inflow and descent wind speed, filter lifespan, working status of fan, lighting, and UV status, plus abnormal prompts, on a color high-definition LCD.
• UV Scheduling: Sets UV sterilization appointments and timing through the built-in calendar and time display.
• Constant Wind Speed: Maintains a constant airflow velocity using wind speed sensors, with interlocking protection across the UV lamp and lighting.
• Front Window Protection: Restricts front window travel through limit protection.
• HEPA Filtration: Captures over 99.995% of dust particles at 0.3 μm using a HEPA filter.
• Filter Alarm: Warns of filter failure or damage, with a low energy consumption standby mode.
• Ergonomic Window: Positions the visual front window at a 10 degree tilt angle that follows ergonomic principles.
• Stainless Steel Interior: Forms the studio wall from SUS304 stainless steel, with a removable brushed stainless steel operating table.
• Clinical Diagnostics: Used for handling potentially hazardous biological samples in clinical diagnostic laboratories.
• Hospital Laboratories: Applied in hospital laboratories where staff protection from biological particles is needed.
• Pharmaceutical Laboratories: Suited to pharmaceutical laboratory procedures involving biological materials.
• Biotechnology Laboratories: Supports biotechnology laboratory work with dangerous or unknown biological particles.
• Microbiology Laboratories: Designed for microbiological procedures that call for aerosol containment
Frequently Asked Questions
1: What type of protection does the BZBN-504 Biological Safety Cabinet offer?
The BZBN-504 provides personal, product, and environmental protection by utilizing a HEPA filtration system and advanced airflow control to maintain a sterile, contamination-free workspace.
2: What kind of control system is integrated in the BZBN-504?
The BZBN-504 features a smart LCD control system that displays real-time data such as wind speed, filter status, UV operation, fan activity, and system alerts.
3: Is the BZBN-504 easy to clean and maintain?
Yes, BZBN-504 is designed with a seamless SUS304 stainless steel interior and a removable worktable, making cleaning easy and reducing contamination risk.
4: Does BZBN-504 require connection to an external exhaust system?
The BZBN-504 includes an exhaust hood and duct. While internal filtration handles most contaminants, external exhaust is recommended for certain hazardous substances or chemical work.
5: How does the BZBN-504 protect against accidental UV exposure?
UV operation is interlocked with the front sash position and lighting system, meaning UV cannot be activated while the window is open or light is on, preventing accidental exposure.
6: What is the main purpose of a biological safety cabinet?
A biological safety cabinet is designed to protect the user, the environment, and the samples from biohazardous or infectious agents through filtered airflow and containment.
7: What kind of filtration system does the cabinet use?
Most BSCs use HEPA filters (High-Efficiency Particulate Air) to trap 99.99% of particles ?0.3 microns.
8: Does the biological safety cabinet offer protection against cross-contamination between samples?
Yes, Class II and III BSCs are designed to minimize cross-contamination with uniform laminar airflow and front barrier protection.