Biological Safety Cabinet BZBN-502
Product1
Product2
Product3

Biological Safety Cabinet BZBN-502

Labzee Biological Safety Cabinet BZBN-502 provides a sterile, contaminant-free workspace for two-user operators with a class 100 cleanliness air level. Its precision airflow at 0.55 m/s inflow and 0.35 m/s downflow ensures safe containment across 80 to 105 Pa, while the split-frame design allows flexible installation. It features HEPA filtration, hybrid air circulation, UV sterilization, and an intelligent control panel with an LCD for complete operational safety, a clean environment, and consistent performance.

$ 5394

Applicable Number Of Users 2
Cleanliness Class 100
Inflow Air Velocity 0.55 m/s
Down Airflow Velocity 0.35 m/s
Noise ≤ 67 dB
Vibrational Half Peak Value ≤ 5 µm
Illuminance ≥ 650 Lux
Ambient Temperature 10 to 30°C
Relative Humidity at 25°C ≤ 70 %
Atmospheric Pressure 80 to 105 Pa
Height of Rack 630 mm
Power 1400 W
Power And Number Of Lamp 30 W, 1 Piece
Power And Number Of UV Light 30 W, 1 Piece
Net Weight 223 Kg
Gross Weight 253 Kg
Internal Dimension 1360 × 580 × 595 mm
Housing Dimension 1500 × 770 × 2135 mm
Inflow HEPA Dimension 1395 × 475 × 70 mm
Exhaust HEPA Dimension 750 × 420 × 90 mm
Packaging Dimension 1760 × 970 × 1690 mm

HEPA Filtration: High-efficiency particle removal for a sterile workspace.

Two-User operators: Designed for two Users to work side‑by‑side at the same time.

Hybrid Air Circulation: External exhaust and internal recirculation for enhanced safety.

UV Sterilization: Automated decontamination cycles for surface disinfection.

Intelligent Control Panel: LCD display for real-time monitoring.

• Laboratories: Sterile workspace for routine biological sample handling.
• Hospitals: Safe processing of infectious specimens and patient samples.
• Research Facilities: Containment for cell culture and molecular biology research.
• Pharmaceutical Labs: Contamination-free preparation of drug compounds.
• Clinical Diagnostics: Safe testing of patient samples and pathology specimens.

Frequently Asked Questions

1: How does the intelligent control system enhance BZBN-502 cabinet operation?

The intelligent control system of BZBN-502 features a high-definition LCD screen that displays real-time airflow speed, filter lifespan, UV and fan status, lighting, power supply alerts, and abnormal system prompts for easy monitoring and control.

2: What type of air circulation does the BZBN-502 use?

The BZBN-502 uses a hybrid air circulation system combining external exhaust and internal recirculation to ensure both safety and clean airflow.

3: Does the BZBN-502 offers any power-saving features?

Yes, BZBN-502 includes a low-energy consumption standby mode that reduces power usage when the cabinet is not actively in use.

4: Can the BZBN-502 be easily installed in constrained lab spaces?

Yes, the BZBN-502 features a split-type, disassembled frame design that allows for flexible assembly and transport through narrow passages or doors.

5: Is the BZBN-502 cabinet noisy during operation?

No, the fan system and internal design aim to minimize noise levels, providing a quieter working environment that supports concentration and reduces fatigue.

6: What is the main purpose of a biological safety cabinet?

A biological safety cabinet is designed to protect the user, the environment, and the samples from biohazardous or infectious agents through filtered airflow and containment.

7: What kind of filtration system does the cabinet use?

Most BSCs use HEPA filters (High-Efficiency Particulate Air) to trap 99.99% of particles ?0.3 microns.

8: Does the biological safety cabinet offer protection against cross-contamination between samples?

Yes, Class II and III BSCs are designed to minimize cross-contamination with uniform laminar airflow and front barrier protection.