$ 3319
| Main Box Dimension | 1200 × 600 × 600 mm |
| Material | PMMA |
| PMMA Thickness | 10 mm |
| Left Round Door | 350 mm |
| Gloves | 4 |
| Transition Box | Yes |
| Transition Box Dimension | 240 × 240 × 240 mm |
| Product Dimension | 120 × 60 × 60 cm |
| Package Dimension | 146 × 74 × 78 cm |
| Net Weight | 95 Kg |
| Gross Weight | 100 Kg |
Built-in Transfer Box: Enables safe tool and sample exchange without disrupting the main chamber atmosphere.
Sealed Chamber: Maintains controlled conditions for air-sensitive handling.
High-Clarity PMMA Structure: 10 mm thick acrylic body ensures durability, chemical resistance, and transparent visibility.
Four Glove Ports: Allows multi-user or dual-hand operations for complex tasks.
Contamination-Free Workspace: Provides isolated, particle-free environment for sensitive materials.
• Biopharma Labs: Used for sterile processing and controlled handling of sensitive biological materials.
• Chemistry Research: Suitable for hazardous sample containment and chemical isolation.
• Aerospace R&D: Applied in precision material handling under controlled conditions.
• Medical Device Research: Used for contamination‑free assembly and testing of medical components.
• Controlled Gas Atmosphere Handling: Used for experiments requiring inert gas purging.
Frequently Asked Questions
1: Can the Acrylic Glove Box Be Used for Powder Handling?
Yes, the sealed environment of the Acrylic Glove Box makes it ideal for handling powders and fine particles. The gloves prevent direct contact while the chamber confines airborne dust. This is especially useful in pharmaceutical or chemical labs. The clear panels also help monitor particle spread. It ensures both user and material safety.
2: Is It Safe to Use the Acrylic Glove Box with Biological Samples?
Yes, biological samples can be handled safely inside the Acrylic Glove Box. The enclosed design limits contamination risks. Latex gloves and a sealed environment prevent cross-contamination. It’s particularly useful for working with sterile or sensitive biological materials. The transition box further reduces external exposure. Routine cleaning is recommended post-use.
3: What Is the Size of the Transition Box?
The transition box size in most models is 240×240×240 mm. It’s compact yet spacious enough to transfer tools, containers, and small samples. The cube design offers balanced pressure distribution. The chamber features tight-sealing doors on both sides. It is equipped with valves and a gauge for pressure control.
4: Can More Than One Person Use the Acrylic Glove Box at the Same Time?
Yes, models with 3 or 4 glove ports can accommodate two users simultaneously. This is ideal for collaborative experiments or handling large components. The glove ports are spaced for ergonomic access. Coordinated use requires careful movement to avoid glove entanglement. Larger models ensure comfort and efficiency during joint tasks.
5: How Is the Acrylic Glove Box Cleaned?
Cleaning involves using mild detergents and a lint-free cloth. Avoid using solvents that may damage the acrylic surface. All corners and seals should be cleaned regularly. The gloves should be sanitized without harsh chemicals. Vacuum systems can assist in removing dust and particles. Proper maintenance extends usability and hygiene.
6: What Is an Acrylic Glove Box Used For?
An Acrylic Glove Box is used to create a sealed and controlled environment for conducting experiments. It helps isolate materials from air, moisture, dust, and contaminants. This makes it suitable for chemical, biological, or electronic research. Users can manipulate objects inside safely through attached gloves. It’s essential for clean and precise lab work.
7: What Materials Are Used in This Acrylic Glove Box?
The Acrylic Glove Box is made of clear, durable acrylic panels, providing high visibility and structural strength. It features latex gloves for hand access, which are soft and flexible. Gas inlet and outlet valves are made of stainless steel, offering durability and corrosion resistance. All materials are chosen for lab safety and reliability.
8: Is the Acrylic Glove Box Airtight?
Yes, the Acrylic Glove Box is designed to be airtight. The front door uses a sealing gasket and latches to prevent any air exchange with the outside. This ensures a stable atmosphere inside, which is crucial for sensitive tasks. Airtightness also protects both users and contents from contamination. It maintains the integrity of experiments.
9: How Do You Introduce Gas Into the Acrylic Glove Box?
Gas is introduced through the stainless steel inlet and outlet valves built into the Acrylic Glove Box. These valves allow you to purge the interior with inert gases like nitrogen or argon. This helps in creating a dry and oxygen-free environment. The process is straightforward and supports many types of scientific experiments. Pressure can be controlled safely.
10: Can the Acrylic Glove Box Be Used for UV Experiments?
Yes, the Acrylic Glove Box can support UV-based experiments. Its clear acrylic body allows limited UV transmission, which is useful for sterilization or polymer curing. However, compatibility depends on the wavelength of UV light used. It’s ideal for microbiology work or UV testing when used properly. Always follow safety guidelines when using UV light.