$ 6549
| Type | Floor-standing horizontal refrigerated shaking incubator, with casters |
| Control | P.I.D. microcomputer controller (environment-scanning chip) |
| Display | Large backlit LCD, dual display of set and measured values |
| Air circulation | Forced convection |
| Oscillation mode | Rotary |
| Drive | Single-axis balancing device (patent ZL 2015 2 0624431.5) |
| Temperature range | 4–60 °C |
| Temperature accuracy / uniformity | ±0.1 °C / ±1 °C |
| Shaking speed | 30–300 rpm in the table (the feature list says 50–300 rpm) |
| Speed accuracy | ±1 rpm |
| Orbit (pendulum amplitude) | Φ25 mm |
| Standard load | 8 × 2,000 mL (feature list: heightening type, flasks up to 5,000 mL) |
| Platform | 1 platform, 920 × 500 mm |
| Inner chamber | 970 × 550 × 350 mm (one value for all four models, so it may not apply to the 211C) |
| External dimensions | 1250 × 740 × 840 mm |
| Package size | 1340 × 860 × 1070 mm |
| Timer | 0–999.59 h, or continuous |
| Programming | Repeat, step, 8-segment curve programming |
| Safety | Upper and lower temperature deviation alarm; upper and lower speed deviation alarm; independent over-temperature protector; door-open stop; leakage protection; chiller overload protection |
| Other functions | Speed storage, power-off recovery, parameter memory, speed and temperature correction, clock, room and measured temperature display, soft start with acceleration ramp |
| Refrigerant | CFC-free R134a |
| Cooling / heating power | 200 W / 800 W |
| Total power / supply | 1120 W; AC 200–240 V, 50–60 Hz |
| Motor | 120 W inverter motor (AC induction, brushless) |
| Chamber material | Imported stainless steel, mirror finish |
| Body material | Castings, channel steel, angle steel and cold-rolled steel plate |
| Ambient conditions | 5–25 °C, humidity 20–90% |
| Gross Weight | 185 Kg |
UV lamp
humidity detection or control
intake pipe
lighting
• Single-Axis Balanced Drive: Keeps energy consumption and noise to a minimum.
• PID Microprocessor Control: Scans the environment for accurate temperature and speed control.
• CFC-Free Refrigeration: Provides safe, environmentally compliant cooling for low-temperature incubation.
• Over-Temperature Protection: Sounds an alarm and cuts power automatically if the unit overheats.
• Power-Off Recovery: Resumes the original program after a sudden power loss.
• Cell Culture: Supports cell growth under controlled temperature and shaking.
• Microbiology: Used for bacterial suspension preparation and culture mixing.
• Solubility Testing: Helps dissolve and test samples under steady agitation.
• Extraction Experiments: Provides agitation during extraction of target compounds.
• Diagnostic Testing: Used for mixing samples in diagnostic test preparation.