$ 1237
| Temperature Range | RT+5 °C to 100 °C |
| Temperature Accuracy | ≤±0.3 °C |
| Temperature Uniformity | ≤±0.3 °C |
| Temperature Stability | ±0.3 °C |
| Time Range | 1 min to 99 h |
| Display Accuracy | 0.1 °C |
| Heating Time | ≤6 min (20 °C to 56 °C) |
| Dimensions (mm) | 145 × 113 × 110 |
| Voltage | DC 24 V / 1.67 A |
| Net Weight | 0.5 Kg |
• Single Temperature Incubation: Runs EO biological indicators at one set temperature.
• Dry Block Heating: Warms test tubes through a thermal block.
• Fast Heating: Brings the block to the set temperature within minutes.
• Accurate Temperature Control: Holds the set temperature with close accuracy.
• Built-in Thermometer: Gives a quick check of incubation temperature.
• Visible Process: Keeps the incubation in view through a transparent design.
• Electronic Calibration: Allows resetting to a local standard.
• Bench Top Design: Sits on a bench top within a small footprint.
• Sterile Processing Departments: Used for incubating EO biological indicators after sterilizer cycles.
• Medical Device Manufacturing: Applied in checking EO sterilization of device batches before release.
• Pharmaceutical & Microbiology Labs: Suited to incubating EO biological indicators for sterility checks.
• Hospital Central Sterile Supply: Supports incubating EO biological indicators from instrument loads.
• Contract Sterilization Providers: Designed for incubating EO biological indicators from processed loads.
Frequently Asked Questions
1: Can the incubation process be visually monitored in the BZBII-501?
Yes, the BZBII-501 features a transparent design, making the incubation process clearly visible for easy monitoring.
2: Is the BZBII-501 compatible with various biological indicator types?
The BZBII-501 supports customizable heating blocks, allowing compatibility with different sample holders and indicator formats.
3: Is the BZBII-501 portable and space-saving?
Yes, the BZBII-501 has a compact design and weighs only 0.5 kg, making it highly portable and suitable for limited-space work environments.
4: What type of biological indicators are compatible with the BZBII-501?
The BZBII-501 is specifically designed for Ethylene Oxide (EO) biological indicators, commonly used in sterilization validation processes.
5: Does the BZBII-501 require regular maintenance?
The BZBII-501 is designed for low-maintenance operation but should be cleaned regularly and calibrated as per your lab's standard protocols.
6: What is a Biological Indicator Incubator used for?
Biological Indicator Incubators are used to incubate biological indicators after sterilization cycles to verify the effectiveness of the sterilization process.
7: Can it be used with all types of biological indicators?
It is compatible with most self-contained biological indicators (SCBIs) and spore strip vials commonly used in sterilization validation.