Labzee Biological Indicator Incubator BZBII-501 runs single temperature incubation of EO biological indicators in a thermal block to verify sterilization cycles. The dry block incubator covers RT+5 °C to 100 °C, and ±0.3 °C accuracy keeps each run on target. It offers a timer from 1 minute to 99 hours to set the incubation time. Heating time from 20 °C to 56 °C is 6 minutes or less, giving a fast start to each incubation.

$ 1237

Temperature Range RT+5 °C to 100 °C
Temperature Accuracy ≤±0.3 °C
Temperature Uniformity ≤±0.3 °C
Temperature Stability ±0.3 °C
Time Range 1 min to 99 h
Display Accuracy 0.1 °C
Heating Time ≤6 min (20 °C to 56 °C)
Dimensions (mm) 145 × 113 × 110
Voltage DC 24 V / 1.67 A
Net Weight 0.5 Kg
  • Block (10mm × 15)
  • Block (12mm × 12)
  • Block (15mm × 8)
  • Block (16mm × 8)
  • Block (9mm × 18)

• Single Temperature Incubation: Runs EO biological indicators at one set temperature.
• Dry Block Heating: Warms test tubes through a thermal block.
• Fast Heating: Brings the block to the set temperature within minutes.
• Accurate Temperature Control: Holds the set temperature with close accuracy.
• Built-in Thermometer: Gives a quick check of incubation temperature.
• Visible Process: Keeps the incubation in view through a transparent design.
• Electronic Calibration: Allows resetting to a local standard.
• Bench Top Design: Sits on a bench top within a small footprint.

• Sterile Processing Departments: Used for incubating EO biological indicators after sterilizer cycles. 
• Medical Device Manufacturing: Applied in checking EO sterilization of device batches before release. 
• Pharmaceutical & Microbiology Labs: Suited to incubating EO biological indicators for sterility checks. 
• Hospital Central Sterile Supply: Supports incubating EO biological indicators from instrument loads. 
• Contract Sterilization Providers: Designed for incubating EO biological indicators from processed loads.

Frequently Asked Questions

1: Can the incubation process be visually monitored in the BZBII-501?

Yes, the BZBII-501 features a transparent design, making the incubation process clearly visible for easy monitoring.

2: Is the BZBII-501 compatible with various biological indicator types?

The BZBII-501 supports customizable heating blocks, allowing compatibility with different sample holders and indicator formats.

3: Is the BZBII-501 portable and space-saving?

Yes, the BZBII-501 has a compact design and weighs only 0.5 kg, making it highly portable and suitable for limited-space work environments.

4: What type of biological indicators are compatible with the BZBII-501?

The BZBII-501 is specifically designed for Ethylene Oxide (EO) biological indicators, commonly used in sterilization validation processes.

5: Does the BZBII-501 require regular maintenance?

The BZBII-501 is designed for low-maintenance operation but should be cleaned regularly and calibrated as per your lab's standard protocols.

6: What is a Biological Indicator Incubator used for?

Biological Indicator Incubators are used to incubate biological indicators after sterilization cycles to verify the effectiveness of the sterilization process.

7: Can it be used with all types of biological indicators?

It is compatible with most self-contained biological indicators (SCBIs) and spore strip vials commonly used in sterilization validation.