$ 1122
| Temperature Setting Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5 °C to 100 °C |
| Temperature Accuracy | ≤ ±0.3 °C |
| Temperature Uniformity | ≤ ±0.3 °C |
| Temperature Stability | ± 0.3℃ |
| Display Resolution | 0.1 °C |
| Heating and Control | Film heating, PID control |
| Heating Time | ≤ 12 min (25 °C to 100 °C) |
| Time Range | 1min to 99h 59min/∞ |
| Sample Groups | Up to 7, each with independent timing |
| Automatic Heating | Yes |
| Automatic Running | Yes |
| Automatic Resume to Run | Yes |
| Safety | Software and hardware over-temperature protection |
| Power | 150 W |
| Voltage | AC 220V or AC 110V, 50/60Hz |
| Fuse | 250V 3A Ф5 × 20 |
| Dimension | 260 × 195 × 150 mm |
| Weight | 2.5 Kg |
• Real-Time Display: Shows settings and running status on screen.
• PID Temperature Control: Regulates temperature through automatic PID control.
• Wide Timer Range: Covers incubation periods from 1 min to 99 h 59 min through a flexible timer.
• Independent Timer: Counts down each sample group separately.
• Multi-Sample Incubation: Handles several sample groups in the same run.
• Automatic Preheating: Preheats the incubator through an automatic function.
• Automatic Running: Runs the incubator through an automatic running function.
• Power Recovery: Restores operation through an automatic power recovery function.
• Temperature Calibration: Offers a calibration function for the incubator temperature.
• Over-Temperature Protection: Protects the incubator through software and hardware protection.
• Microbiology Laboratories: Used for incubating biological indicators from routine sterilizer monitoring.
• Pharmaceutical Laboratories: Applied in checking sterilization cycles with several indicator groups.
• Healthcare Facilities: Suited to incubating biological indicators from instrument sterilization loads.
• Medical Device Manufacturing: Supports batch release checks through multi sample indicator incubation.
• Sterile Processing Departments: Designed for timed incubation of indicators after sterilizer cycles.
Frequently Asked Questions
1: How many samples can the BZBII-502 incubate at once?
The BZBII-502 can incubate up to 7 sample groups simultaneously, each with independent countdown timers.
2: Is the BZBII-502 suitable for all types of biological indicators?
Yes, the BZBII-502 is designed to accommodate various types of biological indicators used in sterilization validation and microbiology testing.
3: How easy is it to operate the BZBII-502 Biological Indicator Incubator?
The BZBII-502 features a user-friendly interface with real-time display, making it easy to set up, monitor, and operate even for new users.
4: Is the BZBII-502 portable for use in different lab settings?
Yes, the BZBII-502 is compact and lightweight, making it easy to move and place in various laboratory environments.
5: How does the BZBII-502 ensure uniform temperature distribution?
The incubator uses advanced film heating technology and PID control to maintain temperature uniformity within ±0.3°C.
6: What is a Biological Indicator Incubator used for?
Biological Indicator Incubators are used to incubate biological indicators after sterilization cycles to verify the effectiveness of the sterilization process.
7: Can it be used with all types of biological indicators?
It is compatible with most self-contained biological indicators (SCBIs) and spore strip vials commonly used in sterilization validation.