Autoclaves from Labzee offer steam sterilization of laboratory glassware, surgical instruments, dental tools, textiles inside a sealed chamber. The range covers laboratory autoclave, autoclave sterilizer designs, including benchtop autoclave, table top autoclave, vertical autoclave, horizontal autoclave, portable autoclave models, with Class B autoclave and pulse vacuum autoclave versions using pre-vacuum sterilization for thorough air removal. The steam sterilizer autoclave machine pairs pressure and temperature control with a drying cycle, safety features including door locks, pressure sensors, overheat protection, and automatic shut-off, supporting sterilization in research, healthcare, dental, clinical settings. ISO and CE-certified, Labzee autoclaves support safe, hygienic workflows through steam sterilization.
Chamber: 100L
Volume: Φ440×650mm
Working Pressure: 0.22Mpa
Working Temperature: 134℃
$ 5969
Chamber Volume: 35 L (Ø300 × 500 mm)
Working Pressure: 0.22 MPa
Working Temperature: 134 °C
Temperature Range: 105–134 °C
Chamber Volume: 50L (Ø340 × 550 mm)
Working Pressure: 0.22 MPa
Working Temperature: 134 °C
Temperature Range: 105–134 °C
$ 5124
Sterilizing Chamber Volume: 16 L (Φ250 × 360 mm)
Working Pressure: 0.22 MPa
Working Temperature: 134 °C
Temperature Adjustment Range: 105 to 134 °C
$ 1743
Sterilizing Chamber Volume: 24L(φ270×410 mm)
Working Pressure: 0.22 MPa
Working Temperature: 134 °C
Temperature Adjustment Range: 105 to 134 °C
$ 1835
Sterilizing Chamber Volume: 20 L (Ø250 × 420 mm)
Maximum Working Pressure: 0.22 MPa
Maximum Working Temperature: 134°C
Temperature Adjustment Range: 105–134°C
$ 1835
Sterilizing Chamber Volume: 24 L (Φ250 × 520 mm)
Maximum Working Pressure: 0.22 MPa
Maximum Working Temperature: 134°C
Temperature Adjustment Range: 105–134°C
$ 2032
Capacity: 20L
Chamber Size: Φ250×420mm
Working Pressure: 0.22MPa
Working Temperature: 134℃
$ 1858
Capacity: 24L
Chamber Size: Φ250×470mm
Working Pressure: 0.22MPa
Working Temperature: 134℃
$ 2422
Capacity: 45 L
Design Temperature: 139°C
Design Pressure: -0.1 to 0.25 MPa
Working Pressure: 0.22 MPa
$ 4647
Chamber: 35L
Volume: Φ318×450mm
Working Pressure: 0.22Mpa
Working Temperature: 134℃
$ 2249
Chamber: 50L
Volume: Φ340×550mm
Working Pressure: 0.22Mpa
Working Temperature: 134℃
$ 3008
Chamber: 75L
Volume: Φ400×600mm
Working Pressure: 0.22Mpa
Working Temperature: 134℃
$ 2985
Chamber: 100L
Volume: Φ440×650mm
Working Pressure: 0.22Mpa
Working Temperature: 134℃
$ 3169
Chamber: 35L
Volume: Φ318×450mm
Working Pressure: 0.22Mpa
Working Temperature: 134℃
$ 2088
Chamber: 50L
Volume: Φ340×550mm
Working Pressure: 0.22Mpa
Working Temperature: 134℃
$ 2456
Chamber: 75L
Volume: Φ400×600mm
Working Pressure: 0.22Mpa
Working Temperature: 134℃
$ 2893
Chamber: 100L
Volume: Φ440×650mm
Working Pressure: 0.22Mpa
Working Temperature: 134℃
$ 3422
Capacity: 100 L
Chamber Volume: 450 × 650 mm
Sterilization Temperature Range: 116℃ to 134℃
Temperature Accuracy: ±1℃
$ 3135
Frequently Asked Questions
1: What can be sterilized in an autoclave?
Autoclaves can sterilize surgical instruments, dental tools, laboratory glassware, textiles, and certain plastics - provided they can withstand high heat and pressure.
2: What safety features do autoclaves have?
Modern autoclaves are equipped with safety valves, automatic shut-off, door lock systems, pressure sensors, and overheat protection to ensure safe operation.
3: What is the drying function in an autoclave for?
The drying cycle ensures instruments are moisture-free after sterilization, preventing microbial re-growth and preserving packaging integrity.
4: How should an autoclave be maintained?
Regular maintenance includes cleaning the chamber, checking gaskets, draining the reservoir, and inspecting valves and filters. Annual calibration and servicing are recommended for optimal performance. Neglecting maintenance can compromise sterilization quality and reduce equipment lifespan
5: Is biological indicator testing necessary for autoclaves?
Yes, biological indicators (BIs) are essential to confirm sterilization effectiveness. They contain resistant spores to ensure the cycle kills even the toughest microbes. Routine BI testing is part of quality assurance in clinical, pharmaceutical, and research labs