$ 2427
| Class | Class N Autoclave |
| Chamber Capacity | 18 L |
| Chamber Size | Φ250 × 350 mm |
| Sterilization Temperature | 121°C / 134°C |
| Sterilization Time (121°C) | Default 30 min; adjustable 30–60 min |
| Sterilization Time (134°C) | Default 10 min; adjustable 10–20 min |
| Working Pressure | 1.1 bar at 121°C; 2.1 bar at 134°C |
| Automatic Discharge | Yes |
| Drying Function | Yes |
| Dry Time | Default 60 min; adjustable 1–60 min |
| Temperature Control Accuracy | Within 0.1°C |
| Safety Protection | Temperature and pressure overload protection |
| Pressure Safety Lock | Door opens only when pressure reaches 0 |
| Safety Door Lock | Cycle starts only when door is properly locked |
| Automatic Pressure Release | Automatically discharges water and steam after cycle completion |
| Power | 1500 VA |
| Electrical Supply | 220–240 V / 50 Hz; 110–120 V / 60 Hz |
| Overall Dimensions (W × H × D) | 483 × 450 × 515 mm |
| Packaging Dimensions (W × H × D) | 63.5 × 57.5 × 52.5 cm |
| Net Weight | 33 kg |
| Gross Weight | 37 kg |
• Two Sterilization Programs: Provides 121°C/1.1 bar and 134°C/2.1 bar cycles for different steam sterilization requirements.
• Sterilization Chamber: Provides a Φ250 × 350 mm chamber for suitable laboratory sterilization loads.
• High-Precision Temperature Control: Maintains high-precision temperature control within 0.1°C.
• Adjustable Sterilization and Drying Time: Allows users to set sterilization and drying durations according to laboratory load requirements.
• Temperature and Pressure Overload Protection: Protects the autoclave against excessive temperature or pressure during operation.
• Pressure Safety Lock: Only allows the door to open when the pressure is 0.
• Safety Door Lock: Prevents the sterilization cycle from starting unless the door is properly locked.
• Heat Drying Function: Removes residual moisture from suitable loads after the sterilization cycle.
• Automatic Pressure Release: Automatically discharges water and steam after the cycle is over.
• Laboratory Loads: Handles heat-resistant glassware, instruments, and other compatible solid loads requiring steam treatment.
• Dental Clinics: Used for compatible reusable dental instruments requiring controlled steam sterilization cycles.
• Veterinary Practices: Supports treatment of reusable heat-resistant instruments used in routine veterinary procedures.
• Tattoo Studios: Accommodates compatible heat-resistant tattoo instruments requiring steam-based microbial control.
• Cosmetic Practices: Processes reusable heat-resistant instruments used for cosmetic and aesthetic procedures.