Horizontal Clean Bench

Horizontal Clean Bench from Labzee offers laboratory workstations designed to provide a Class 100 controlled, particle-free environment through horizontal laminar airflow. Each HEPA clean bench filters airborne particles from the air moving across the workspace, reducing contamination during sample handling and preparation. Models include UV lamps and low-noise fans, with several workspace widths to match different bench layouts. Explore the laboratory clean bench range to keep the workspace cleaner during daily laboratory work.

Clean Level

Wind Speed

Noise Level

Vibration Semi-Peak Value

Illumination Intensity

Horizontal Clean Bench BZZC-501

Clean Level: Class 100 (U.S. Federal 209E)

Wind Speed: 0.32 to 0.66m/s

Noise Level: Less Than 65dB

Vibration Semi-Peak Value: Less Than 3um

$ 2259

Horizontal Clean Bench BZZC-502

Clean Level: Class 100 (U.S. Federal 209E)

Wind Speed: 0.32 to 0.66m/s

Noise Level: Less Than 65dB

Vibration Semi-Peak Value: Less Than 5um

$ 2732

Horizontal Clean Bench BZZC-503

Clean Level: Class 100 (U.S. Federal 209E)

Wind Speed: 0.32 to 0.66m/s

Noise Level: Less Than 65dB

Vibration Semi-Peak Value: Less Than 3um

$ 2474

Horizontal Clean Bench BZZC-504

Clean Level: Class 100 (U.S. Federal 209E)

Wind Speed: 0.32 to 0.66m/s

Noise Level: Less Than 65dB

Vibration Semi-Peak Value: Less Than 4um

$ 3176

Frequently Asked Questions

1: What is a Horizontal Clean Bench?

A Horizontal Clean Bench is a laminar airflow workstation designed to provide a particle-free, sterile environment for sensitive processes in labs, pharmaceuticals, and electronics. It uses HEPA/ULPA filters to deliver ISO Class 5 air horizontally, protecting samples from contamination.

2: How Does a Horizontal Clean Bench Work?

Air is drawn through a HEPA/ULPA filter and blown horizontally across the work surface, creating a laminar flow that minimizes turbulence. This ensures a contamination-free zone for tasks like sample preparation, electronics assembly, or sterile compounding.

3: What does Class 100 (US Federal 209E) mean?

Class 100 means the clean bench maintains less than 100 particles (more than 0.5 micrometer) per cubic foot, equivalent to ISO Class 5 standards - ideal for sensitive laboratory work.

4: Is the 0.32-0.66m/s wind speed adjustable?

Yes, our clean bench offers adjustable airflow within this range to accommodate different applications while maintaining laminar flow integrity.

5: What is the typical internal chamber volume?

Labzee models offer internal volumes ranging from approximately 236 to 437 liters, depending on the specific model.

6: Do Labzee benches include UV sterilization?

Yes, Labzee Horizontal Clean Benches come with built-in UV sterilization systems to disinfect the workspace before and after use.