Labzee Benchtop Heating Incubator BZHI-502 ensures precise, uniform heating with advanced thermal control in an 81-liter stainless-steel chamber. It operates within a temperature range of RT+5°C to 80°C, offering fine control with a resolution of 0.1°C. The high-visibility LCD screen enables real-time display of temperature and timer settings for efficient operation. It features a microprocessor controller with temperature correction and programmable timing. Our Benchtop Heating Incubator BZHI-502 is ideal for a wide range of heating applications in research and industrial laboratories.
$737.00
| Chamber Volume | 81 L |
| Temperature Range | RT+5 to 80℃ |
| Temperature Fluctuation | ±0.5°C |
| Temperature Uniformity | ±1℃ |
| Temperature Resolution | 0.1℃ |
| Power Supply | AC 220V, 50Hz |
| Power Consumption | 700W |
| Chamber Size (W×D×H) | 45×40×45 cm |
| Exterior Size (W×D×H) | 73×53×69 cm |
| Package Dimension | 85×66×86 cm |
| Net Weight | 50 Kg |
| Gross Weight | 75 Kg |
2 Grid Racks (Expandable to 6)
Labzee Benchtop Heating Incubator BZHI-502 is ideal for sample incubation, reagent warming, microbial growth, drying tasks, enzyme reactions, and general heating in research, pharmaceutical, and industrial laboratories.
Frequently Asked Questions
1: How does the BZHI-502 ensure consistent thermal uniformity across the 81L chamber?
Benchtop Heating Incubator BZHI-502 utilizes a precision-engineered air duct circulation system combined with a microprocessor controller to maintain uniform temperature distribution, achieving ±1°C uniformity even during extended heating cycles.
2: What level of temperature control resolution does this unit offer, and why is it relevant?
Benchtop Heating Incubator BZHI-502 provides a fine resolution of 0.1°C, allowing researchers to precisely set and monitor target temperatures—critical for applications requiring high thermal accuracy such as enzyme reactions and stability testing.
3: Can the BZHI-502 support complex time-temperature profiles for protocols requiring staged heating?
Yes, with the optional multi-segment programmable control upgrade, users can set multiple ramp and soak stages, ideal for protocols involving stepwise thermal transitions.
4: What kind of insulation and sealing technology is used to minimize heat loss?
Benchtop Heating Incubator BZHI-502 is sealed with a high-quality silicon sealing ring and features a heat-insulated safety handle, both of which help retain internal temperature and protect the operator from accidental burns.
5: How is system redundancy handled in the event of primary temperature control failure?
Benchtop Heating Incubator BZHI-502 includes a backup mechanical thermostat that automatically engages to maintain safe operating temperatures, ensuring uninterrupted functionality during control system failure.
6: Is the unit compatible with external data systems or logging devices?
Yes, optional RS485 communication interface is available for integration with lab information systems or external data loggers, facilitating remote monitoring and data collection.
7: How does the timing function contribute to unattended operation?
The programmable timer allows users to set run times up to 9999 minutes, supporting long-duration experiments without the need for manual intervention, while ensuring precise start-stop control.
8: Are there contamination control options available?
Yes, an optional UV sterilizer can be integrated for periodic decontamination, particularly valuable in applications sensitive to microbial cross-contamination or for maintaining aseptic conditions.
9: What are Benchtop Heating Incubators used for?
Benchtop Heating Incubators are used to maintain a controlled, heated environment for laboratory processes such as incubation, drying, and sample testing.
10: How is temperature controlled in Benchtop Heating Incubators?
Our Benchtop Heating Incubators use microprocessor-controlled systems for precise temperature regulation and stability.
11: Is the heat evenly distributed in Benchtop Heating Incubators?
Yes. A forced air or air duct circulation system ensures uniform heat distribution across the chamber.
12: What materials are used for the chambers?
Labzee Benchtop Heating Incubators are typically made of high-quality stainless steel, which is durable, corrosion-resistant, and easy to clean. Many models also feature removable, easy-to-clean shelves.
13: Are Benchtop Heating Incubators suitable for small laboratory spaces?
Yes. Benchtop Heating Incubators compact designs are ideal for laboratories with limited workspace.
14: What safety features do Benchtop Heating Incubators have?
Common safety features include leakage protection and backup mechanical thermostats to prevent overheating and ensure continuous operation.
15: Can Benchtop Heating Incubators be used for long-duration experiments?
Yes. With their precise temperature stability and programmable timers, Benchtop Heating Incubators support both short-term and long-duration experiments.
16: Do Benchtop Heating Incubators have user-friendly interfaces?
bsolutely. Labzee Benchtop Heating Incubators feature clear LCD displays for real-time monitoring and easy operation.