$ 3100
| Sectioning Thickness Range | 0.5-100 µm |
| Section Thickness Setting | 0.5-5 µm (0.5 µm step); 5-20 µm (1 µm step); 20-60 µm (5 µm step); 60-100 µm (10 µm step) |
| Trim Thickness Range | 1-600 µm |
| Trim Thickness Setting | 1-600 µm (20 µm step); 20-50 µm (5 µm step); 50-100 µm (10 µm step); 100-600 µm (50 µm step) |
| Feeding Drive Mode | Stepper Motor Driven; Stable and Precise |
| Specimen Head Memory | Remembers Last Feeding Location for Quick Repositioning |
| Specimen Head Retraction | 0-250 µm adjustable |
| Specimen Head Coarse Feed Speed | 900-2000 µm/s |
| Specimen Head Fine Feed Speed | 100-900 µm/s |
| Horizontal Stroke of Specimen Head | 25 ±1 mm |
| Vertical Stroke of Specimen Head | 60 ±1 mm |
| Specimen Positioning | Disc With 360° Rotation And 0-Digit Indication |
| Specimen Head Return Function | Fast Return in 2000 µm/S with Stop Control |
| Handwheel Lock | Lock Positions at 6 and 12 O’clock |
| Knife Holder Compatibility | High/Low Profile Blades; Horizontal Travel: 48 Mm; Angle: 0-15° |
| Refrigeration Positions | 4-Point Refrigeration: Cryo Chamber, Specimen Head, Knife Holder, Shelves |
| Temperature Display | Displays Temperatures of All 4 Refrigerated Zones |
| Temperature Setting | Specimen Head: -5 °C to -50 °C |
| Refrigeration Method | Single-Compressor Cooling System |
| No. of Freezing Stations | 3 |
| Power Consumption | 370 W |
| Product Dimension | 590 × 715 × 445 mm |
| Package Dimension | 815 × 690 × 595 mm |
| Net Weight | 70 Kg |
| Gross Weight | 88 Kg |
| Packaging Type | Wooden Case |
• Microtome Blades
• Power Cord (2 m): 1 pc
• Fuse (10 A): 4 pcs
• Sample Tray with Rubber Ring (32 × 28 × 3 mm): 5 pcs
• Handwheel with Plug Cover and Positioning Pin: 1 pc
• Fixed Heat Absorber (Cold Hammer): 1 pc
• Wheel Mounting Screw (M5 × 20 mm): 1 pc
• Handle: 1 pc
• Waste Liquid Tray: 1 pc
• E-Type Knife Holder: 1 pc
• Waste Box: 1 pc
• Writing Brush: 1 pc
• Tweezers: 1 pc
• Embedding Medium (OCT): 1 pc
• Blade: 1 pc
• Small Screwdriver (3 × 50 mm): 1 pc
• Hexagon Wrench: 1 pc
• Multi-Point Refrigeration: Quickly cools the cryo chamber and key components for cryostat sectioning.
• Compact Cryochamber: Space-saving design for easy specimen handling.
• Specimen Head Memory: Stores the specimen position for quick return to the preset location.
• Anti-Collision Protection: Automatic knife protection helps prevent equipment damage during operation.
• Precise Specimen Feeding: Micron-level adjustment supports accurate tissue sectioning.
• Color Touchscreen Display: Clearly displays operating functions and parameters.
• Induction Lighting: Sensor-activated lighting with adjustable brightness improves visibility during sectioning.
• Clinical Laboratories: Supports frozen tissue sectioning and preparation for microscopic examination.
• Hospitals and Pathology Laboratories: Enables tissue section preparation for pathological examination.
• Medical Research Laboratories: Used for fresh tissue sectioning in biological and histological studies.
• Biotechnology Laboratories: Designed for tissue sample preparation and microscopic analysis.
Frequently Asked Questions
1: Can you explain the sectioning thickness range and settings of the BZBCR-501?
The cryostat provides a sectioning thickness range from 0.5 to 100?µm with finely tunable step settings. These increments allow for delicate to thicker tissue sections, ensuring versatility for different histological requirements.
2: How does the feeding drive system improve performance?
It uses a stepper motor-driven feeding mode that offers stable and precise control during tissue sectioning. The system also remembers the last feeding location for quick repositioning, enhancing workflow efficiency.
3: What refrigeration capabilities does this cryostat include?
The BZBCR-501 has a single-compressor cooling system that maintains four refrigerated zones: cryo chamber, specimen head, knife holder, and shelves. It features real-time temperature displays for all zones to ensure optimal freezing conditions.
4: What are the specimen handling and positioning features?
The specimen head supports horizontal and vertical strokes with 360° rotational positioning and digit indication. It also offers fast return functions and handwheel locks, providing precise and reproducible sectioning.
5: Can you describe the defrosting and power specifications of this unit?
This benchtop cryostat operates on 220V power supply with a power consumption of 370 W. Although defrosting options are not explicitly detailed, its efficient refrigeration system minimizes frost buildup during operation.
6: When is a Benchtop Cryostat used in the lab?
It is used for cutting thin sections of frozen tissue for rapid diagnostic or research purposes. The cryogenic environment preserves sample morphology during sectioning. It is commonly used in intraoperative pathology.
7: Can the unit maintain a consistent cryogenic temperature?
Yes, Benchtop Cryostats feature precise digital temperature control for the chamber and specimen. Consistent cooling ensures section quality and reproducibility. Settings can typically be adjusted to match different sample types.
8: Can frozen tissues be cut at varying thicknesses?
Yes, section thickness is adjustable, often between 1 and 60 µm. This allows flexibility for different diagnostic or research requirements. Smooth thickness adjustment ensures accurate results.
9: When should the chamber be cleaned and disinfected?
The cryostat chamber should be cleaned after every session to prevent contamination. Use cryo-safe disinfectants and remove residual tissue and debris. Routine cleaning extends equipment life and improves hygiene.
10: Can it be used in small labs with limited space?
Yes, the benchtop design is ideal for compact workspaces without sacrificing performance. Its portable form factor makes it easy to relocate as needed. It suits mobile labs, universities, and small pathology units.